Integra DHC-40.1 (B) Service Manual page 10

Av controller
Table of Contents

Advertisement

A
B
SCHEMATIC DIAGRAM-4
1
AREA-1
1
DACC
2
DACSW
3
DACFL
4
DACFR
5
DACSBL
6
DACSBR
7
DACSL
8
DACSR
9
OTPF
10
AD_L
11
AD_R
12
2
+12VDG
13
+12VDG
14
GNDDG
15
GNDDG
16
GNDDG
17
+15V
18
-15V
19
GNDA
20
GNDA
20
GNDA
19
GNDA
18
-15V
17
+15V
16
GNDDG
15
GNDDG
14
GNDDG
13
+12VDG
12
+12VDG
11
AD_R
3
10
AD_L
9
OTPF
8
DACSR
7
DACSL
6
DACSBR
5
DACSBL
4
DACFR
3
DACFL
2
DACSW
1
DACC
SBLSP
07
SLSP
06
LSP
05
CSP
04
4
RSP
03
SRSP
02
SBRSP
01
1
2
3
4
5
6
7
1
VOLH
2
SEC1H
3
VPRO
4
IPRO
5
5
6
3.3V
7
THERMAL
1
DGND
2
HPDET
3
RL_Front
4
RL_Surr
5
RL_SurrBK
6
RL_FW
7
RL_FH
8
RL_C
9
VOLH
10
SEC1H
11
VPRO
12
IPRO
13
3.3V
14
THERMAL
15
6
16
+24V
R6690
09
1W-8.2
GND_RL
08
GND_SBR
07
GND_SR
06
GND_FR
05
GND_C
04
GND_FL
03
GND_SL
02
GND_SBL
01
7
< CAUTION >
DHC-40.1 use only AREA-1, 2, 3, 4, 5 & 6.
8
C
D
U0020
SPEAKER TERMINAL-1 PC BOARD
BATRM-0083-1D
(PART-8)
SP TARMINAL
S1.3C
L6605
22
R6605
R6615
22
SBL
J6655
NC
L6603
S1.3C
S1.3C
L6600
R6603
22
R6613
22
R6600
22
SL
R6610
22
L
J6653
NC
J6650
NC
L6602
S1.3C
R6602
22
L6601
S1.3C
22
R6612
R6601
22
C
R6611
22
J6652
R
NC
J6651
NC
L6604
S1.3C
R6604
22
L6606
S1.3C
22
R6614
R6606
22
SR
R6616
22
J6654
SBR
NC
J6656
NC
RN1226
RLY_F
Q6601
RLY_Sur
RN1226
RLY_SB
Q6602
RLY_FW
RN1226
Q6603
RLY_FH
RN1226
Q6604
RN1226
RN1226
Q6605
relay control
Q6606
DHC-40.1
E
F
BATRM-0083
R6691 390(1/2W)
HPL
HPR
R6692 390(1/2W)
RL6609
GND_SBL
1
6
C
3
2
C
4
5
1SS133
D6609
C6609
103J
AREA-2
RL6607
1
6
SL
3
2
SL
SR
4
5
SR
1SS133
D6607
C6607
103J
RL6600
6
1
L
2
3
FL
R
5
4
FR
1SS133
D6600
C6600
103J
D6610
1SS133
C6602
103J
1
6
SBL
3
2
SBL
SBR
4
5
SBR
RL6602
1SS133
D6603
C6603
103J
1
6
SBL
3
2
LW
SBR
4
5
RW
RL6603
NRL-2P5A-DC24-158
1SS133
D6605
C6605
103J
6
1
SBL
2
3
SBR
5
4
RH
RLY_C
RL6605
NRL-2P5A-DC24-158
AREA-3
C6639 -- 6649
CODE
MODEL
TYPE
T7
A7
T8
A8
D
NC
---
NC
---
T7
TX-SR-707, DTR-40.1
J
---
NC
---
NC
TX-SA707
A7
M
472J
---
472J
---
T8
TX-NR807, DTR-50.1
A8
TX-NA807
NOTE
THE COMPONENTS IDENTIFIED BY MARK
ARE CRITICAL FOR SAFETY.
REPLACE ONLY WITH PART NUMBER SPECIFIED.
VOLTAGE (MEASURED WITH VOLTMETER)
IS DC VOLTAGE. (NO INPUT SIGNAL)
ELECTROLYTIC CAPACITORS
(
)
ARE IN uF/WV.
ALL CAPACITORS ARE IN pF/50WV UNLESS OTHERWISE NOTED.
EX) 030
3pF 330
33pF 331 330pF 333
0.033uF
ALL RESISTORS ARE IN OHMS 1/4WATTS UNLESS OTHERWISE NOTED.
THE THICK LINES ON PC BOARD ARE THE PRINTING SIDE OF THE PARTS.
EX)
PRINTING SIDE
CIRCUIT IS SUBJECT TO CHANGE FOR IMPROVEMENT.
G
H
I
U0022
SPEAKER TERMINAL-2 PC BOARD
BATRM-0085-1D
AREA-4
to H/P Jack
JL4103A
NSCT-5P97
4
3
2
1
E6611
HPL
1
1
HPL
HPR
2
2
HPR
P6605
HPDET
3
3
HPDET
DGND
4
4
DGND
2
5
5
GND_SBL
C6655
LW
6
6
LW
102J
LH
7
7
LH
GND_SL
8
8
GND_SL
SL
9
9
SL
GND_C
10
10
GND_C
C
11
11
C
P6607
2
C6657
102J
P6609
P6600
2
2
C6659
102J
C6650
3
102J
1
BATRM-0085
JL6607A
P6603
JL6607B
2
P6610
C6653
3
2
102J
C6660
1
102J
P6602
2
Not use
C6652
3
102J
U0021
1
PRIMARY POWER SUPPLY PC BOARD
P6604
BAPS-0084-1D
2
AREA-5
PRI POWER SUPPLY
1SS133
C6654
3
102J
D933
MTZJ3.6B
1SS133
D934
1
D935
P6601
2
C6651
3
102J
1
P6606
4
3
2
1
D930 1SS133
2
E901
D931 1SS133
C6656
3
NPT-1519
102J
*
1SS133
1
9
2
8
D923
1
1SS133
3
7
4
6
D921
P6608
1SS133
5
D924
2
1SS133
C6658
3
D922
102J
R921
47(1/2W)
D925
1SS133
1
C902
104J
3
2
1
F901C
F901D
RL901
F901
4
1
1
F901A
F901B
C901
103M/275VAC
P921C
P902B
LIST
BAPS-0084
connect Inlet Socket
connect AC-SW
or AC Cord
or insert Short Pin (2009991127UL)
AC CORD
J902
TX-SR707,TX-SA707,DTR-40.1
Mount
TX-NR807,TX-NA807,DTR-50.1
No mount
Mount
DHC-40.1
P902B
TX-SR707,TX-SA707,DTR-40.1
No mount
TX-NR807,TX-NA807,DTR-50.1
Mount
No mount
DHC-40.1
for 707DC,DD,DF
CAUTION
THIS SYMBOL LOCATED NEAR THE FUSE INDICATES
FOR CONTINUED PROTECTION
AGAINST FIRE HAZARD, REPLACE
THAT THE FUSE USED IS SLOW OPERATING TYPE
ONLY WITH FUSE OF SAME TYPE
FOR CONTINUED PROTECTION AGAINST FIRE FUSE
V
A
HAZARD,REPLACE WITH SAME TYPE FUSE. FOR FUSE
AND RATING INDICATED.
RATING REFER TO THE MAKING ADJACENT TO THE SYMBOL.
ATTENTION
CAUTIONF AFIN D'ASSURER UNE PROTECTION
CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST
PERMANENTE CONTRE LES RISQUES
A LENT, E POUR UNE PROTECTION PERMANENTE,N'UTILISER
D'INCENDIE, REMPLACER UNIQUEMENT
QUE DES FUSIBLES DE MEME TYPE. CE DARNIER EST
PAR UN FUSIBLE DE MEME TYPE
V
A
INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE.
ET CALIBRATION COMME INDIQUE.
DHC-40.1
J
K
3
1
3
1
3
1
3
1
POFF
5
+12VD
4
MPUGND
3
+10VS
2
POWERD
1
4
3
2
1
AREA-6
E902
5
T901
Main Trans
4
3
3
2
1
S1
S2
5
4
3
2
S3
1
6
1
S4
5
2
4
3
1
2
S5
1
F901
TYPE
T7
A7
T8
A8
DHC-40.1
D
10A 125V
---
12A 125V
---
5A 125V
J
10A 125V
10A 125V
15A 125V
15A 125V
---
M
T5.0AL250V
---
T6.3AL250V
---
---
T902
TYPE
T7
A7
T8
A8
DHC-40.1
D
1520JQ
---
1520JQ
---
1520JQ
J
---
1520JQ
---
1520JQ
---
M
1520GQ
---
1520GQ
---
---

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents