MAINTENANCE

5 MAINTENANCE
5.1

MAINTENANCE INTERVALS

Service level
Lubricating oil
check oil level
change oil and oil filter cartridge
check lubricating oil pressure
Cooling
check cooling liquid level
system
check and clean radiator
check hoses
check cooling system
Exhaust
check exhaust
Nuts & bolts
check all and tighten where necessary
Electrics
check all electrical connections
check/adjust V-belt tension
check battery (acid level, connections)
Fuel system
drain water from tank
replace fuel filter
check fuel hoses
check injection nozzles and injection pressure
check injection pump
Air supply
check air strainer and filter element
Cylinder head
Retighten cylinder head bolts and readjust valve
clearance
*
Whichever comes first.
 Can be done by user. Corrective action to be taken whenever necessary.
 WhisperPower service centre to be contacted.
5.2

ALTERNATOR

The alternator does not require maintenance.
5.3

ENGINE

5.3.1

Preliminary instructions

The first service on the engine should be carried out after 50
running hours. This period also applies after a major overhaul.
During the first 50 hours, the engine should receive special
attention:
Long periods of light or no load running in the first 50
hours may lead to cylinder glazing and high oil
consumption.
For the same reason it is of the greatest importance to use
the right oil specification.
18
break-in
before
after
each
35-50 h
start
 (12M)
5.3.2

Bleeding the fuel lines

When the engine is started up for the first time or after it has
run out of fuel, the fuel system may need to be primed. Push
the start button activating the electric system and activating the
fuel pump. When more time is needed to bleed, hold the
"Start/Stop" button on the local control panel (so not on the
remote panel). While the button is held, the pump will work,
but the unit will not start. Hold as long as necessary to bleed
the system
5.4

REGULAR MAINTENANCE

5.4.1

General precautions

All regular maintenance can be carried out when the enclosure
is open. When oil and dirt have gathered in the enclosure,
measures have to be taken to prevent oil from being spilled.
W-GV/2, W-GV/3, W-GV/3+, W-GV 8, W-GV 10 and W-GV 15 — June 2017 — EN
1
2
3
every
every
every
200 h/
400 h/
800 h/
6M*
12M*
24M*
/
4
every
1600 h/
36M*
/
(3200h)

Hide quick links: