USERS MANUAL FOR
Belt Power
belt driven generator
W-BD 3.5 / W-BD 5: 230V 50Hz
WHISPER POWER BV
Kelvinlaan 82
9207 JB Drachten
The Netherlands
Tel.: +31-512-571550
Fax.: +31-512-571599
www.whisperpower.eu
V3 November 2011
V1 June 2010

Advertisement

Table of Contents
loading

Summary of Contents for Whisper Power Belt Power W-BD 3.5

  • Page 1 USERS MANUAL FOR Belt Power belt driven generator W-BD 3.5 / W-BD 5: 230V 50Hz WHISPER POWER BV Kelvinlaan 82 9207 JB Drachten The Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599 www.whisperpower.eu V3 November 2011 V1 June 2010...
  • Page 2: Table Of Contents

    CONTENTS CONTENTS: INTRODUCTION ................................4 General ................................4 Service and maintenance ........................... 4 Guarantee ................................4 Liability ................................5 Identification ............................... 5 1.5.1 General .............................. 5 1.5.2 Identification plate..........................5 INFORMATION ................................6 Safety ................................. 6 2.1.1 General .............................. 6 2.1.2 Electrical safety ..........................
  • Page 3 CONTENTS 5.2.1 Checking the windings ........................19 SPARE PARTS LIST ..............................19 EN / W-BD3.5/W-BD5 BeltPower / November 2011...
  • Page 4: Introduction

    GUARANTEE of the Belt Power first launched in June 2010 This manual is valid for the following models: Whisper Power guarantees that this Belt Power generator has been built according to good workmanship, according Part number Description...
  • Page 5: Liability

    Long term running with high load on or too low rpm cause overheating problems and can damage the generator and Whisper Power does not accept responsibility for damage, V-belt transmission. injuries or casualties which are the result of operation of...
  • Page 6: Information

    INTRODUCTION factor one. When calculating a load one should always take into account the power factor or cos. phi of this load. The power should never exceed the nominal power as shown on the identification plate. Power is rated at an ambient temperature of 25ºC. For higher temperatures the Belt Power has to be de- rated.
  • Page 7: Electrical Safety

    • switched on. On request Whisper Power Extension cables must be suitable for outdoor use: can adjust the software to change this 3.5 kW model: Use 16 Amp rated cable (2.5mm feature so that the power comes back maximum 100 m.
  • Page 8: Operation

    INFORMATION 2.1.5 Operation STORAGE When the on/off switch is in the on-position when the vehicle (boat) engine starts the inverter will immediately • After transporting the Belt Power check for damage generate 230V to the outlet. Ensure that all appliances not before installation.
  • Page 9: Application

    INFORMATION via a remote control panel. The remote control panel parallel! Many of the latest generation combi’s can run in includes 5 meter remote cable. 10 or 15 m cable can be parallel! The Power Belt inverter and combi could also ordered as option with the Belt Power.
  • Page 10: Technical Information

    INFORMATION TECHNICAL INFORMATION The Belt Power is a very advanced high tech variable speed electric power supply system. It is based on the latest inverter and generator technology and offers a very stable sinus and high efficiency. 2.5.1 Generator The Three Phase 230V Generator (200Volt up to 340V) is made according to a dedicated design and offers usable power over a large frequency band.
  • Page 11: Technical Data

    INFORMATION 2.5.7 Technical data GENERAL Model W-BD 3.5/ W-BD 5 RPM/Power W-BD 3.5: 2500 rpm/1 kW, 4000 rpm up to 15000 rpm/ 3.5 kW. (Refer to diagram) W-BD 5: 3300 rpm/1 kW, 7000 rpm up to 15000 rpm/ 5 kW. (Refer to diagram) Continuous Power 3.5 kW /5 kW 230V 50Hz pure sine wave Peak Power...
  • Page 12: Lay Out Control Wiring

    INFORMATION 2.5.8 Lay out control wiring Fuse: W-BD 3,5 3 Amp. W-BD 5 12/15 Amp. Fig. 6: Electrical Diagram November 2011/ W-BD3.5/W-BD5 BeltPower / EN...
  • Page 13: Operation

    OPERATION 3 OPERATION • GENERAL that the requested/needed electrical power is adequate for the nominal output (if not: the The Belt Power is operational after full installation and Power Box starts with auto-protection, the red connecting the remote control panel. LED is continuously lit).
  • Page 14: Maintenance

    GENERATOR/ELECTRICAL FAULTS 5.1.2 Service address If you cannot correct a problem with the aid of the malfunction table, contact your Whisper Power Service Centre or WhisperPower Netherlands for an extended Beware of parts which are live! The generator service list, service@whisperpower.nl.
  • Page 15: Display Indication Overview

    TROUBLE SHOOTING 5.1.3 Display indication overview Interruption excitation Description activation Critical Display Brief description GENER- WARNING LOW RPM ALARM and end of activation Alarm ATION YELLOW ORANGE Interruption GREEN output OPERATION FAULT TAKE AWAY THE CAUSE OF THE FAULT AND RESET Voltage lower than limit AC Under Output voltage too low...
  • Page 16: Fault Finding Table When The System Is Not Working

    TROUBLE SHOOTING 5.1.4 Fault finding table when the system is not working November 2011/ W-BD3.5/W-BD5 BeltPower / EN...
  • Page 17: Fault Finding Table When The System Stops Working

    TROUBLE SHOOTING 5.1.5 Fault finding table when the system stops working EN / W-BD3.5/W-BD5 BeltPower / November 2011...
  • Page 18: Overview Display Modes

    TROUBLE SHOOTING 5.1.6 Overview display modes November 2011/ W-BD3.5/W-BD5 BeltPower / EN...
  • Page 19: Special Procedures Generator

    TROUBLE SHOOTING SPECIAL PROCEDURES GENERATOR 5.2.1 Checking the windings When the basic conditions are in good order and a generator failure is suspected one should measure the output voltage on the generator and on the cable output to the inverter. When the voltage between the phases of the output terminals of the generator is wrong (should be between 200 and 360 Volt) one could also measure the resistance...
  • Page 20 Kelvinlaan 82, 9207 JB Drachten, The Netherlands www.whisperpower.com/ sales@whisperpower.nl...

This manual is also suitable for:

Belt power w-bd 5W-bd 3.5W-bd 54130100041302000

Table of Contents