Page 1
MODEL: CB OPERATING INSTRUCTION AND PARTS MANUAL CB-3010 CB-3530 CB-4020 For technical assistance or the SHARK dealer nearest you, call 1-800-771-1881 or visit our website at www.shark-pw.com #97-714...
The model and serial numbers will be found on a decal attached to the pressure washer. You should record both serial number and date of purchase and keep in a safe place for future reference. SHARK CB • 97-714 • REV. 4/05...
(GFCI) power cord. 11. Protect from freezing. 12. Be certain all quick coupler fittings are secured be- fore using pressure washer. 13. Do not allow acids, caustic or abrasive fluids to pass through the pump. SHARK CB • 97-714 • REV. 4/05...
Page 5
19. Keep operating area clear of all persons. 20. Do not overreach or stand on unstable support. Keep good footing and balance at all times. 21. Follow the maintenance instructions specified in the manual. SHARK CB • 97-714 • REV. 4/05...
In- tor valve. Warm water will discharge onto floor and cludes safety latch. cool water will allow the pump protector to seal. This system prevents internal pump damage. SHARK CB • 97-714 • REV. 4/05...
STEP 5: Connect the high pressure hose to the outlet dis- charge fitting. Push coupler collar forward until secure. Connect the garden hose to pump water inlet. Inspect in- lets. CAUTION: Do not run the pump without water or pump damage will result. SHARK CB • 97-714 • REV. 4/05...
NOTE: For a more gentle rinse, select the white 40° or green 25° nozzle. To scour the surface, select the yellow 15° or red 0° nozzle. To apply deter- gent select the black nozzle. SHARK CB • 97-714 • REV. 4/05...
If you run your pressure washer for 3-5 minutes without pressing the trigger on the spray gun, circulating water in the pump can reach high temperatures. When the SHARK CB • 97-714 • REV. 4/05...
2. Restart pressure washer and let it run briefly (about 5 seconds) until water no longer discharges from the high pressure outlet. SHARK CB • 97-714 • REV. 4/05...
Broken or weak suction or delivery Check and replace if necessary. valve spring Foreign matter in valves Check and clean if necessary. Worn bearings Check and replace if necessary. Excessive temperature of water Reduce to below 140 SHARK CB • 97-714 • REV. 4/05...
Page 12
Replace coil after the timer and unloader switch have been tested. MACHINE WILL NOT Timer is defective Join wires 15 and 16 together on timer. If TURN ON WHEN works, replace timer. SWITCH IS PUSHED SHARK CB • 97-714 • REV. 4/05...
Check pump oil level before first use. Change pump oil after first 50 hours and every month or 500 hours thereaf- ter. Use SAE 30 weight oil. Estimated Operating Estimated Operating Date Oil Changed Hours Since Last Date Oil Changed Hours Since Last Month/Day/Year Oil Change Month/Day/Year Oil Change SHARK CB • 97-714 • REV. 4/05...
Page 23
FITNESS FOR A PARTICULAR PURPOSE. SHARK does not authorize any other party, including authorized Dealers, to make any representation or promise on behalf of SHARK, or to modify the terms, conditions, or limitations in any way. It is the buyer’s responsibility to ensure that the installation and use of SHARK products conforms to local codes. While SHARK attempts to assure that its products meet national codes, it cannot be responsible for how the customer chooses to use or install the product.
Page 24
Form #97-714 • Revised 4/05 • Printed in U.S.A.
Need help?
Do you have a question about the CB-3010 and is the answer not in the manual?
Questions and answers