User's Manual
Parameter
[EnableMgmtTwoFactorAu
thentication]
http-port
[HTTPport]
[DisableWebConfig]
[ResetWebPassword]
[WelcomeMessage]
Version 7.0
[0] = Disable (default)
[1] = Enable
Enables Web login authentication using a third-party, smart card.
[0] = Disable (default)
[1] = Enable
When enabled, the device retrieves the Web user's login username from
the smart card, which is automatically displayed (read-only) in the Web
Login screen; the user is then required to provide only the login
password.
Typically, a TLS connection is established between the smart card and
the device's Web interface, and a RADIUS server is implemented to
authenticate the password with the username. Thus, this feature
implements a two-factor authentication - what the user has (the physical
card) and what the user knows (i.e., the login password).
Defines the LAN HTTP port for Web management (default is 80). To
enable Web management from the LAN, configure the desired port.
Note: For the parameter to take effect, a device reset is required.
Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified. In addition, the
following pages can't be accessed: Web User Accounts, TLS Contexts,
Time and Date, Maintenance Actions, Load Auxiliary Files, Software
Upgrade Wizard, and Configuration File.
Note: For the parameter to take effect, a device reset is required.
Resets the username and password of the primary ("Admin") and
secondary ("User") accounts to their default settings ("Admin" and
"Admin" respectively), and deletes all other users that may have been
configured.
[0] = (Default) Password and username retain their values.
[1] = Password and username are reset.
Notes:
For the parameter to take effect, a device reset is required.
You cannot reset the username and password through the Web
interface (by loading an ini file or on the AdminPage). To reset the
username and password:
SNMP:
1) Set acSysGenericINILine to WEBPasswordControlViaSNMP =
1, and reset the device with a flash burn (set
acSysActionSetResetControl to 1 and acSysActionSetReset to
1).
2) Change the username and password in the
acSysWEBAccessEntry table. Use the following format:
Username acSysWEBAccessUserName: old/pass/new
Password acSysWEBAccessUserCode: username/old/new
Enables and defines a Welcome message that appears on the Web
Login page for logging in to the Web interface.
The format of the ini file table parameter is:
[WelcomeMessage ]
703
51. Configuration Parameters Reference
Description
Mediant 4000 SBC