Multiple Interface Table Configuration Summary And Guidelines - AudioCodes Mediant 4000 SBC User Manual

Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

12.4.2 Multiple Interface Table Configuration Summary and Guidelines

The Interface table configuration must adhere to the following rules:
Multiple Control and Media interfaces can be configured with overlapping IP
addresses and subnets.
The prefix length replaces the dotted-decimal subnet mask presentation and must
have a value of 0-30 for IPv4 addresses and a value of 0-64 for IPv6 addresses.
One OAMP interface must be configured and this must be an IPv4 address. This
OAMP interface can be combined with Media and Control.
At least one Control interface must be configured.
At least one Media interface must be configured.
Multiple Media and/or Control interfaces can be configured with an IPv6 address.
The network interface types can be combined:
Example 1:
Example 2:
Example 3:
Each network interface can be configured with a Default Gateway. The address of the
Default Gateway must be in the same subnet as the associated interface. Additional
static routing rules can be configured in the Static Route table.
The interface name must be configured (mandatory) and must be unique for each
interface.
For IPv4 addresses, the 'Interface Mode' column must be set to IPv4 Manual. For IPv6
addresses, this column must be set to IPv6 Manual or IPv6 Manual Prefix.
Note:
validation tests. If any errors occur during this validation phase, the device sends an
error message to the Syslog server and falls back to a "safe mode", using a single
interface without VLANs. Ensure that you view the Syslog messages that the device
sends in system startup to see if any errors occurred.
User's Manual
One combined OAMP-Media-Control interface with an IPv4 address
One OAMP interface with an IPv4 address
One or more Control interfaces with IPv4 addresses
One or more Media interfaces with IPv4 interfaces
One OAMP with an IPv4 address
One combined Media-Control interface with IPv4 address
One combined Media-Control interface with IPv6 address
Upon device start up, the Interface table is parsed and passes comprehensive
136
Mediant 4000 SBC
Document #: LTRT-41730