8.6 Batch Weighing
This indicator has a 10 channel PLU (Product Look Up) memory. To access a memory
channel, press a number from 0 to 9, then press the F1 key.
This section applies if your indicator has the batching application active. To select the
batching mode, press the MODE key. BATCHING will be briefly displayed. The
batching application allows you to set three outputs based on three progressively larger
weights. There are two possible modes of batching; Auto or Manual. These are
selected in a password protected menu. See the Service Manual. Each are explained
below.
AUTO
MANUAL
Model E1010 Indicator User Instructions
As weight is added to the scale and the first output point is reached, OP1
annunciator lights and Output #1 is activated. When weight reaches the
second cutoff, OP2 annunciator lights and Output #2 activates. When
weight reaches the third cutoff, OP3 annunciator lights and Output #3
activates.
In manual mode, after you begin the batching process, you must press the
F1 key to activate each subsequent output after each output weight is
reached.
Figure 8.3 Output flowchart
39