(4) Keep press ENTER to show the information.
Please refer to DS2 servo manual for detailed alarm information.

Set to default value

The following are the steps of set to default value. The operations must be done
when servo is OFF.
(1) Press STATUS/ESC to enter auxiliary function.
(2) Press INC or DEC, set the group no. to 4, press ENTER to confirm.
(3) Keep press ENTER, it will show 0 and blink.
(4) Set the value to 1, keep press ENTER to make it effective.
(5) Re-power on the drive.

External monitor

In auxiliary function, choose F5-00, it will show C-OUT. COM1 is available, control
panel is invalid. User can debug the servo through PC.
Press STATUS/ESC to exit.

5. Parameter setting

The following steps show how to change the value of P3-09 from 2000 to 3000.
(1) Press STATUS/ESC, change to parameter setting status, press ENTER to
confirm.
(2) The second LED will blink, press INC or DEC to change the value to 3, keep
press ENTER to confirm.
(3) The last two LEDs will blink at this time, press INC or DEC to change the value to
09, keep press ENTER to confirm.