You can view the recording status on the Record Status interface (Main Menu>Status>Record).
5 recording types are selectable: Normal, Motion Detection, Alarm, Motion | Alarm and Motion
& Alarm.
Up to 8 time periods can be set for each day and each of the time periods cannot be overlapped.
5.
Click the Set button of More Settings to configure the pre-record and post-record time.
Pre-record: Normally used for the event (motion or alarm) triggered record, when you want to record
before the event happens. For example, when an alarm occurs at 10:00, if the pre-record time is set as
5 seconds, the camera records the alarm at 9:59:55.
Post-record: After the event finished, the video can also be recorded for a certain time. For example,
when an alarm ends at 11:00, if the post-record time is set as 5 seconds, the camera records till
11:00:05.
6.
Optionally, you can select the camera and click Copy to copy the current settings to the selected camera.
7.
Click Apply to save the settings and click OK to exit.

4.2 Configuring Motion Detection Record

Purpose:
In the motion detection record, once a motion event occurs, the device starts to record and multiple linkage
actions will be triggered.
Steps:
1.
For detailed steps, you can refer to 7.2.5 Configuring Motion Detection.
2.
Enter the Record Settings interface, and select Motion as the record type to set the arming schedule of
motion detection record.
Main Menu > Basic Settings > Record Settings > Schedule

4.3 Configuring Alarm Triggered Record

Purpose:
Rail Network Video Recorder User Manual
Figure 4. 3 Record Schedule Settings