MODEL : AOU36RML
PROCESS
Assemble PCB ASSY.
MAIN PCB
REGULATIONS
Certainly set PWB ASSY under the 3 hooks of INVERTER BOX A.
Before it is temporary fix of PWB ASSY, As shown in the Fig.3-6, pull out the wires of PWB ASSY.
After it is temporary fix of PWB ASSY, As shown in the Fig.7-11, pull out the wires of PWB ASSY.
Don't forget to take a cushion D101 (DIODE BRIDGE).
Don't bend foot D101 (DIODE BRIDGE).
W12 YELLOW,W13 BLUE
(MAIN PCB)
WIRE WITH TERMINAL
Don't forget to take a cushion(D101).
Don't bend foot (D101).
Fig.7
1
INVERTER BOX A
R E P L A C E ME N T P A RT S
USED
PARTS
03-39
1
INVERTER BOX A
2
MAIN PCB
3
SCREW,TAPPING
Fig.8
3
SCREW, TAPPING
2
MAIN PCB
Fig.9-11
Through this hole.
Temporarily fix!