Outdoor Fan Control - Fujitsu ASU18RMLQ Service Instruction

Split type room air conditioner
Hide thumbs Also See for ASU18RMLQ:
Table of Contents

Advertisement

4. OUTDOOR FAN CONTROL

(1). Fan Speed
The speed of outdoor unit fan motor is determined at outside temperature and compressor rotation.
( Table 2 : Target fan speed )
AOU24/36RML
Frequency rise
Frequency down
Outdoor temperature
>
Tout 45
=
>
45>Tout 38
=
>
38>Tout 31
=
>
31>Tout 26
=
>
26>Tout 22
=
>
Cooling
22>Tout 18
=
18>Tout 12
>
=
>
12>Tout 7
=
>
7>Tout 3
=
>
3>Tout -3
=
-3>Tout
>
Tout 24
=
>
24>Tout 20
=
>
20>Tout 16
=
>
16>Tout 12
=
Heating
>
12>Tout 5
=
>
5>Tout -1
=
>
-1>Tout -6
=
>
-6>Tout -11
=
-11>Tout
AOU24/36RML
Frequency rise
Frequency down
Outdoor temperature
>
Tout 45
=
>
45>Tout 38
=
>
38>Tout 31
=
>
31>Tout 26
=
>
26>Tout 22
=
>
Cooling
22>Tout 18
=
>
18>Tout 12
=
>
12>Tout 7
=
>
7>Tout 3
=
3>Tout -3
>
=
-3>Tout
>
Tout 24
=
>
24>Tout 20
=
>
20>Tout 16
=
>
16>Tout 12
=
Heating
>
12>Tout 5
=
>
5>Tout -1
=
>
-1>Tout -6
=
>
-6>Tout -11
=
-11>Tout
( Table 4 : Outdoor fan speed )
Speed
Mode
Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating
Upper Fan
AOU24RML
Lower Fan
Upper Fan
AOU36RML
Lower Fan
Compressor rotation [Hz]
<
<
10 F<20
20 F<30
=
=
<
<
7 F<17
17 F<27
=
=
HI
HI
HI
HI
HI
HI
MED
HI
LOW
MED
LOW
MED
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
S-LOW
LOW
MED
MED
HI
HI
HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
Compressor rotation [Hz]
<
<
60 F<70
70 F<80
=
=
<
<
57 F<67
67 F<77
=
=
HI
HI
HI
HI
S-HI
S-HI
HI
HI
HI
HI
HI
HI
MED
HI
MED
MED
LOW
MED
LOW
LOW
LOW
LOW
MED
MED
MED
MED
HI
HI
HI
HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
S-HI
780
780
780
780
780
780
780
780
850
900
850
900
850
900
850
900
<
<
30 F<40
40 F<50
50 F<60
=
=
<
<
27 F<37
37 F<47
47 F<57
=
=
Fan rotation
HI
HI
HI
HI
S-HI
S-HI
S-HI
HI
HI
MED
HI
MED
MED
MED
LOW
MED
MED
S-LOW
LOW
LOW
S-LOW
LOW
LOW
S-LOW
S-LOW
LOW
S-LOW
S-LOW
S-LOW
LOW
LOW
MED
LOW
LOW
MED
MED
HI
HI
HI
HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
<
<
80 F<90
90 F
=
=
<
<
77 F<87
87 F
=
=
Fan rotation
HI
HI
HI
HI
S-HI
S-HI
S-HI
S-HI
HI
HI
HI
HI
HI
HI
MED
HI
MED
MED
LOW
MED
LOW
LOW
MED
HI
MED
HI
HI
HI
HI
HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
H-HI
HI
MED
780
780
400
400
780
780
400
400
780
780
400
400
780
780
400
400
01-07
<
=
<
=
HI
HI
HI
HI
HI
HI
(rpm)
LOW
S-LOW
300
300
200
200
300
300
200
200
300
300
200
200
300
300
200
200

Advertisement

Table of Contents
loading

Table of Contents