Troubleshooting - kozy heat CHASKA 29-ROCK Installation And Operation Manual

Direct vent gas fireplace insert
Hide thumbs Also See for CHASKA 29-ROCK:
Table of Contents

Advertisement

13.0 TROUBLESHOOTING

ATTENTION: Troubleshooting must be performed by a qualified
technician.
Before proceeding with the steps in the following troubleshooting
guide,
Verify proper 120VAC power supply to the control module.
Verify the control module battery pack and the remote
control batteries are fresh and installed with correct polarity.
Issue
Pilot will not light
Pilot will not stay lit
Pilot flame always on, or
will not extinguish
Main burner flame will not
light
Cause
Electrical power interrupted or
disconnected
Wiring disconnection
Gas supply turned of
No LP (propane) gas in tank
Low gas pressure
Pilot lame not making contact
with the lame rectiication
sensor on the pilot assembly
Pilot adjustment screw not
sealed
Control system set to CPI mode
ON/OFF rocker switch in OFF
position
Gas supply turned of
Low gas supply
Wiring disconnection or
improper wiring
Plugged main burner oriice
Pilot lame
Remote control not working
properly
No call for heat
Verify all connections between the wire harnesses and the
system components are proper and positive.
Verify the communication link is established between the
remote control and the IFC module.
Verify inlet pressure meets the recommended inlet pressure.
If necessary, adjust line pressure regulator.
Restore electrical power to appliance or use battery back-up.
Ensure batteries are fully charged if using battery back-up as
power source.
Use wiring schematic (Figure 10.1 on page 24) to determine all
wiring connections are secure and correct.
Check remote shut-of valves from the appliance. Usually there is
a valve near the main gas line. There may be more than (1) valve
between the appliance and main gas line.
Check LP (propane tank). Reill if necessary.
Consult a plumber or a gas supplier.
Can be caused by situations such as a bent line, too narrow
diameter or pipe, or a low line pressure.
Verify the pilot lame envelopes the top of the lame sensor and
extends far enough onto burner for ignition.
To adjust pilot lame, turn pilot adjustment screw on the gas valve
clockwise to decrease lame, and counterclockwise to increase
lame.
Seal pilot adjustment screw. Do not over-tighten.
Set control system to IPI (see Section 11.8.3 on page 28).
Switch rocker switch to ON position.
Check for multiple shut-ofs in the supply line. Verify gas supply is
turned on.
Consult with plumber or gas supplier.
Check LP (propane) tank. Reill if necessary.
Check for faulty or incorrect wiring.
Remove blockage.
Verify the pilot lame is properly directed to ignite burner. See pilot
lame troubleshooting above.
Replace batteries.
Verify remote control is powered ON and thermostat operation is
turned OFF.
Soultion
TROUBLESHOOTING 33