3-2 Camera Adjustment

Note : How to adjust the camera system.
1) EEPROM stores confirmed adjustment value of each adjustment step.
2) DSP (Digital Signal Process : ICD01-Main PCB) digitalizes the camera signal.
3) When changing ICD02-Main PCB of EEPROM, readjust Main PCB. While changing LCD PCB
and CVF PCB- always readjust each part.
Since EEPROM stores confirmed adjustment value of each adjustment step, readjusting must be
performed in order to store the changed data.
4) Adjust the following items after changing LENS Ass'y.
ΠLens Zoom Track
´ Auto HALL
ˇ Auto IRIS
5) Adjust the following items after changing EEPROM and Camera Main PCB.
ΠLens Zoom Track
´ Zoom VR Center
ˇ Auto HALL
¨ Auto IRIS
ˆ Auto White Balance (indoor)
Ø Auto White Balance (outdoor)
3-2-1 Adjustment Preparation
1) Before you start
ΠUse the buttons on the SET key when adjusting Camera.
´ When changing the adjustment item, please press the "EASY-Q" or "DISPLAY" buttons on the Set.
ˇ You can change the adjustment value to Press the W( )T( ) button..
¨ Press the push the "OK" Button when storing confirmed adjustment value of each adjustment step
in EEPROM.
ˆ The OSD shows "OK" after finishing each adjustment step.
Ø In order to exit the adjustment mode, disconnect the power source.
2) Function of each buttons on the Sst Key
Buttons
OK Button push (Confirm)
T( ) (Data Down)
W( ) (Data Up)
EASY-Q (Mode Up)
DISPLAY (Mode Down)
Samsung Electronics
<Table 3-3>
Stores changed value in the adjustment and auto adjustment mode.
Changes data in the adjustment state.
Changes mode.
Alignment and Adjustments
Description
3-3