TROUBLE SHOOTING
1
Press the Thermostat screen. If screen does not illuminate then replace
batteries.
Battery Replacement:
Un-clip the Thermostat from its cradle by sliding the Thermostat
upwards.
Using a flat bladed screwdriver pop off the rear cover.
Replace batteries.
Refit battery cover.
Batteries should operate for approximately 18 to 24 months.
Only good quality alkaline batteries are to be used.
2
If warning triangle is shown then press it.
If "Zone 1 Fault" shown refer to Location Guidelines (overleaf).
If "Boiler Fault" shown, check boiler display and refer to boiler installation
manual.
3
If Time / Day at top left of display is incorrect, change by pressing "Menu" >
"Help & Settings".
4
If Central Heating will not switch on check Target Room Temperature is at least
1°C greater than Actual Room Temperature. If not press radiator symbol at
bottom left of screen until "On" is highlighted then rotate outer ring clockwise.
If Central Heating will not switch off press radiator symbol until "Off" is
highlighted.
5
Check power to boiler is on (boiler display should be on).
6
If boiler transceiver left hand RF light is off, refer to Location Guidelines
(opposite).
7
For Logic Combi C Boilers - ensure boiler Mode Knob is in Winter position.
For Vogue Gen2 Combi Boilers - ensure Central Heating knob is fully clockwise.
8
If the fault persists then isolate the boiler, remove 1 Thermostat battery and repeat
Quick Start Guide instructions from Step 6 (see "INSTALLATION").
9
If the Touch Thermostat replaced an existing thermostat, ensure that boiler
installer connection link wire is in place (see boiler manual).
WEEE DIRECTIVE 2012/19/EC
Waste Electrical and Electronic Equipment Directive
At the end of the product life, dispose of the packaging and product in a
corresponding recycling centre.
Do not dispose of the unit with the usual domestic refuse.
Do not burn the product.
Remove the batteries.
Dispose of the batteries according to the local statutory requirements and not
with the usual domestic refuse.