Download Print this page

IDEAL Touch Installation Manual page 2

Thermostat & transceiver combi
Hide thumbs Also See for Touch:

Advertisement

INSTALLATION
1. Isolate electrical power to the boiler.
2. Remove the blanking plate by inserting flat
blade screwdriver into slot situated centrally at
bottom of blanking plate.
3. Remove link wire plug & keep in a safe place.
4. Connect the transceiver electrical plug.
5. Locate and push the transceiver assembly into the
boiler.
6. Insert only 3 batteries into the Thermostat
(noting correct polarity).
7. Turn electrical power back on to the boiler and
immediately insert the fourth battery into the
Thermostat.
8. Hold the thermostat
approximately 2 metres
away from the boiler and
"CONNECTING TO BOILER" will
be displayed on your screen.
In the unlikely event that commissioning is unsuccessful (e.g. central heating will not switch on or will not
switch off), electrically isolate the boiler, remove 1 battery and repeat from step 6.
Blanking
Plate
9. After approximately 60 seconds
"Set System Time" will be
displayed on your screen. Use up
and down arrows to set the time.
Once time is set press "DONE"
Slot
Transceiver
10. "Set System Date" will be
displayed on your screen. Use up
and down arrows to set the date.
Once date is set press "DONE".