Air Top 2000 STC
1

Statutory regulations governing installation

The Air Top 2000 STC heater has been type-tested and approved in accord-
ance with ECE-R 10 (EMC) and ECE-R 122 (heater).
For approval number see Chapter 16, "Technical data".
Primarily, the stipulations of Part I and of Annex 7 to the Regulation ECE-R
122 must be observed for the installation.
NOTE:
The stipulations of this regulation are binding under the framework
of the Directive 70/156/EEC and/or 2007/46/EC (for new vehicle mod-
els from 29/04/2009) and should also be observed in countries where
there are no specific regulations.
See Chapter 1.2, "Excerpt from the directive ECE-R 122 Part I and Annex
7" and Chapter 1.3, "Excerpt from the directive ECE-R 122 Annex 9".
ATTENTION:
Failure to follow the installation instructions and the notes contained therein
will lead to all liability being refused by Webasto. The same applies if repairs
are carried out incorrectly or with the use of parts other than genuine spare
parts. This will result in the invalidation of the type approval for the heater
and therefore of its homologation / EC type licence.
1.1.
Application of combustion heaters in vehicles for the transpor-
tation of dangerous goods.
Vehicles used for the purpose of transporting dangerous goods are type
approval tested in accordance with ECE R 105. The following measures are
derived for our combustion heaters.
Statutory regulations governing installation
• The electrical cable/wiring harness must be sufficiently dimensioned to pre-
vent overheating. The electrical cable/wiring harness must be sufficiently
insulated. All electrical circuits must be protected by fuses or automatic cir-
cuit breakers.
• The cables must be installed and firmly secured such that the wirings are
adequately protected against mechanical and thermal stress.
• The combustion heaters must be type-tested in accordance with ECE R 122
(equivalent to EC/2001/56 in the version EC/2006/119) and comply with
Annex 9 - Additional regulations for vehicles used for transporting danger-
ous goods.
• The combustion heaters and their exhaust gas piping system must be de-
signed, arranged, protected or covered so as to prevent any unacceptable
risk of heating or ignition of the load.
• In the event of a leak in the fuel line, the fuel must drain to the ground
without coming into contact with hot parts of the vehicle or the load.
• The exhaust system as well as the exhaust pipes shall be so directed or pro-
tected to avoid any danger to the load through heating or ignition. Parts of
the exhaust system situated directly below the fuel tank must have a mini-
mum clearance of 100 mm or be protected by a heat shield.
• It must only be possible to switch the combustion heater on manually. Pro-
gramming devices shall be prohibited.