Combustion air supply
Air Top 2000 STC
8
Combustion air supply
Under no circumstances may the combustion air be taken from areas
occupied by persons. The combustion air intake opening must not face in
the direction of travel. It must be arranged in such a way that it cannot
become clogged with dirt.
NOTE:
It is recommended to install an intake silencer if the length of the intake hose
is less than 0.6 m.
NOTE:
Using a combustion air line, the combustion air must be taken from a
position that is as cool as possible and protected from splash water.
Only use the supplied and Webasto-approved combustion air lines for this
purpose.
The combustion air opening must not be below the fording height permitted
for the respective vehicle.
See statutory installation requirements for further regulations.