Waste Toner Near-Full/Full Detection Control - Olivetti d-Color 201MF Theory Of Operation

Table of Contents

Advertisement

Theory of Operation Ver. 1.0 Sep. 2008
15.3.3

Waste toner near-full/full detection control

A. Waste toner level detection mechanism
• The waste toner level is detected by the actuator and the waste toner full sensor. The
actuator is turned in synchronization with the toner collecting screw that is provided in
the waste toner box.
*Cross section
Toner collecting screw
Waste toner full sensor (PS8)
Actuator: Lower position
Actuator
Toner collecting screw
Y109670-2
Waste toner box
Waste toner full sensor (PS8)
A02FT2C018AA
Theory of Operation
15. Toner collecting section
Actuator
A02ET2C544AA
Actuator: Upper position
A02FT2C019AA
75