Samsung AS12SGGE Training Manual page 46

Wall mounted type
Hide thumbs Also See for AS12SGGE:
Table of Contents

Advertisement

Details for Operation Property
7.
FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending on both the
difference between setting and the room temperature.
8.
COMPULSORY OPERATION :
For operating the air conditioner without the remote control.
*The operating is the same function that AUTO MODE in the
remote controller.
9.
SWING : BLADE-H is rotated vertically by the stepping
motor.
*Swing Set : Press the
button under the remote control
is displayed on LCD the
down. If the one more time press the
location is stop.
10. SETTING THE ON/OFF TIMER. :
*ON TIMER : The On Timer enables you to switch on the
air conditioner automatically after a given period of time.
You can set the period of time from 30 minutes to 24 hours.
*OFF TIMER : The Off Timer enables you to switch off the
air conditioner automatically after a given period of time.
You can set the period of time from 30 minutes to 24 hours.
(Cont.)
and the blades move up and
button, blades
FEATURES & OPERATION
11. SELF DIAGNOSIS
Description
Indoor unit room temperature sensor
error(open or short)
Indoor unit heat exchanger tempera-
ture sensor error(open or short)
Indoor fan motor malfunction
EEPROM error
Option error(option wasn't set up or
option data error)
: Lamp off
12. BUZZER SOUND : Whenever the ON/OFF button is pressed
or whenever change occurs to the condition which is set up
or select, the compulsory operation mode, buzzer is sound-
ed "beep".
6
LAMP of Display Monitor
ENERGY
TURBO
OPERATION
TIMER
SAVING
: Lamp flickering
SAMSUNG | 45