Samsung AS12SGGE Training Manual page 28

Wall mounted type
Hide thumbs Also See for AS12SGGE:
Table of Contents

Advertisement

Installation Diagram of Indoor Unit and Outdoor Unit
5-2. Installation Diagram of Indoor Unit and Outdoor Unit
A
Indoor unit gas leak test check point
Indoor unit
Piping
2
Piping may be laid to the rear, left, right or down.
Right
Rear
Rear
• Wrap the refrigerant pipes and the drain hose up
in the abgorbent pad and the vinyl thape.
• Triply wind the pipes and hose to the end of the
indoor unit with the absorbent pad (make intervals
of 20mm)
300 mm
minimum
600 mm
minimum
B
Drain hose installation
Cut the piping hole
3
sloped slightly
1
Tape vinyl
Left
125 mm
or more
600 mm
minimum
15metres
maximum
Cut the piping hole
sloped slightly
300 mm or more
7metres maximum
300 mm
minimum
* The designs of the unit and Connectionvalue are
subject to Change according to the model.
5
INSTALLATION
125 mm
or more
SAMSUNG | 27