Indoor unit
AS07P2GED
AS18PJGB
SC07APGD
AS18PJGE
SC07ZP2D
SC18AP0D
AS09P2GBD
SC18ZPJ
AS09P2GED
AS24P6GBD
SC09APGD
AS24P6GED
SC09ZP2D
SC24AP6D
AS12P4GBD
SC24ZP6D
AS12P4GED
SC12APGD
SC12ZP4D
(Cool)
(Refrigeración)
(Refroidissement)
(Refrigeração)
(Kühlen)
Outdoor unit
US07P2GED
US18PJGB
SC07APGDX
US18PJGE
SC07ZP2DX
SC18AP0DX
US09P2GBD
SC18ZPJX
US09P2GED
US24P6GBD
SC09APGDX
US24P6GED
SC09ZP2DX
SC24AP6DX
US12P4GBD
SC24ZP6DX
US12P4GED
SC12APGDX
SC12ZP4DX
(Raffreddamento)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung IAS18PJGE/AFR

  • Page 1 OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION ISTRUZIONI PER L’USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG Indoor unit Outdoor unit AS07P2GED AS18PJGB US07P2GED US18PJGB SC07APGD AS18PJGE SC07APGDX US18PJGE SC07ZP2D SC18AP0D SC07ZP2DX SC18AP0DX AS09P2GBD SC18ZPJ US09P2GBD SC18ZPJX AS09P2GED AS24P6GBD US09P2GED US24P6GBD SC09APGD AS24P6GED SC09APGDX US24P6GED SC09ZP2D...
  • Page 2: Safety Precautions

    Safety Precautions The following safety precautions must be taken when using your air conditioner. Risk of electric shock. Can cause injury or death. Disconnect all WARNING remote electric power supplies before servicing, installing or cleaning. This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
  • Page 3: Table Of Contents

    Contents REPARING YOUR AIR CONDITIONER Safety Precautions ........View of the Unit .
  • Page 4: View Of The Unit

    View of the Unit The design and shape are subject to change according to the model. Indoor Unit Room temperature sensor Air Inlet Auto grille On/Off switch Air filter Remote Control Sensor (under the grille) Air flow blades (outlet) Operation indicator Set temperature &...
  • Page 5 Outdoor Unit US07P2GED SC07ZP2DX US09P2GBD US09P2GED SC09ZP2DX US12P4GBD US12P4GED SC12ZP4DX Air Inlet(Rear) Air Outlet Connection Valve Outdoor Unit SC07APGDX SC09APGDX SC12APGDX Air Inlet(Rear) Air Outlet Connection Valve (inside) Outdoor Unit US18PJGB US18PJGE SC18ZPJX Air Inlet (Rear) Air Outlet Connection Valve (inside) Outdoor Unit SC18AP0DX...
  • Page 6: Remote Control-Buttons And Display

    Remote Control - Buttons and Display Operating mode AUTO, COOL, Remote control DRY, FAN) transmission indicator Battery discharge indicator Turbo mode Fan speed Temperature setting Anions indicator Air flow direction Sleep mode Off Timer setting On Timer setting Energy saving On/Off button Temperature adjustment buttons...
  • Page 7: Getting Started

    etting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features.
  • Page 8: Inserting The Remote Control Batteries

    Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
  • Page 9: Selecting The Automatic Operating Mode

    Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the optimum temperature and the fan speed is selected automatically. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 10: Cooling Your Room

    Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 11: Changing The Room Temperature Quickly

    Changing the Room Temperature Quickly The Turbo cooling function is used to cool your room as quickly as possible. You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
  • Page 12: Removing Excess Humidity

    Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 13: Airing Your Room

    Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 14: Selecting Energy Saving Mode

    Selecting Energy Saving Mode If you wish to save energy when using your air conditioner, select the Energy saving mode with the Energy saving button. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 15: Generating Anions

    Generating Anions The air conditioner can generate anions with an ionizer in the indoor unit. Since it is an additional function, you can select it any mode, even when the air conditioner is turned off. Press the button. Result: The air conditioner generates anions. The indoor unit beeps.
  • Page 16: Adjusting The Air Flow Direction Vertically

    Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. Press the button one or more times as required.
  • Page 17: Adjusting The Air Flow Direction Horizontally

    Adjusting the Air Flow Direction Horizontally There are two sets of inner air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. Adjust each set of inner blades to the required position, by pushing or pulling them sideways.
  • Page 18: Setting The On Timer

    Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the button one or more times until the required time is displayed.
  • Page 19: Setting The Off Timer

    Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the button one or more times until the required time is displayed.
  • Page 20: Setting The Sleep Timer

    Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of 6 hours. If you wish to switch the unit off at a specific time, refer to page 19.
  • Page 21: Operating Recommendations

    Operating Recommendation Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically.
  • Page 22: Temperature And Humidity Ranges

    Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes.
  • Page 23: Solving Common Problems

    Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not Check that the breaker used for the air conditioner is switched on. operate at all Check that the operation indicator on the indoor unit is on;...
  • Page 24: Cleaning Your Air Conditioner

    Cleaning Your Air Conditioner For the best use of your air conditioner, you must clean it every two weeks regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you IMPORTANT have switched off the breaker used for the unit. Slide the lower front grille down.
  • Page 25: Cleaning Deodorizing And Bio Filters (Option)

    Cleaning Deodorizing and Bio Filters (Option) To remove minute dust particles and odors, deodorizing and Bio filters are installed in the air conditioner. You should clean the filters every 3 months. 07/09/12 Open the upper front grille by pulling right and left sides of the grille. Pull out the deodorizing and Bio filters.
  • Page 26 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: ELECTRONICS...

Table of Contents