Arrays; Configuring The Physical Drives Into An Array Dramatically - HP ML110 G1 User Manual

Proliant storage server
Hide thumbs Also See for ML110 G1:
Table of Contents

Advertisement

Analyze current corporate and departmental structure.
Analyze the current file server structure and environment.
Plan properly to ensure the best configuration and use of storage.
• Determine the desired priority of fault tolerance, performance,
and storage capacity.
• Use the determined priority of system characteristics to
determine the optimal striping policy and RAID level.
Include the appropriate number of physical drives in the arrays to
create logical storage elements of desired sizes.

Arrays

With an array controller installed in the system, the capacity of several
physical drives can be logically combined into one or more logical
units called arrays. When this is done, the read/write heads of all the
constituent physical drives are active simultaneously, dramatically reducing
the overall time required for data transfer.
NOTE:
Depending on the storage server model, array configuration may not
be possible or necessary.
Figure 4 Configuring the physical drives into an array
dramatically improves read/write efficiency
Because the read/write heads are active simultaneously, the same amount
of data is written to each drive during any given time interval. Each unit of
data is termed a block. The blocks form a set of data stripes over all the
hard drives in an array, as shown in
P1
P2
HP ProLiant Storage Server user guide
L1
P3
Figure
5.
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents