Arrays

See
Figure
9. With an array controller installed in the system, the capacity of several physical drives
(P1–P3) can be logically combined into one or more logical units (L1) called arrays. When this is
done, the read/write heads of all the constituent physical drives are active simultaneously, dramatically
reducing the overall time required for data transfer.
NOTE:
Depending on the storage server model, array configuration may not be possible or necessary.
P1
Figure 9 Configuring arrays from physical drives
Because the read/write heads are simultaneously active, the same amount of data is written to each
drive during any given time interval. Each unit of data is termed a block. The blocks form a set of data
stripes over all the hard drives in an array, as shown in
S1
B1
S2
B4
S3
B7
S4
B10
Figure 10 RAID 0 (data striping) (S1-S4) of data blocks (B1-B12)
For data in the array to be readable, the data block sequence within each stripe must be the same.
This sequencing process is performed by the array controller, which sends the data blocks to the drive
write heads in the correct order.
A natural consequence of the striping process is that each hard drive in a given array contains the
same number of data blocks.
NOTE:
If one hard drive has a larger capacity than other hard drives in the same array, the extra capacity is
wasted because it cannot be used by the array.

Fault tolerance

Drive failure, although rare, is potentially catastrophic. For example, using simple striping as shown in
Figure
10, failure of any hard drive leads to failure of all logical drives in the same array, and hence to
data loss.
To protect against data loss from hard drive failure, storage servers should be configured with fault
tolerance. HP recommends adhering to RAID 5 configurations.
L1
P2
P3
gl0042
B3
B2
B6
B5
B8
B9
B11
B12
gl0043
Figure
10.
HP ProLiant ML350 G5 Storage Server