Kaba 52 Operating Instructions Manual

Kaba 52 Operating Instructions Manual

52 series

Advertisement

52 SERIES
M
52 & T52
ODELS
O
I
PERATING
NSTRUCTIONS
The following instructions cover Model 52 & T52 lock operations. The lock models
operate the same except for an additional feature that is found in the Model T52 that
allows you to program a time delay for lock opening and an opening window for the lock.
After entering the proper combination(s) for the lock, the bolt cannot be retracted until the
time delay has expired. Once the delay has expired, the bolt must be retracted within the
opening window.
SUPER MASTER CONTROL
The Super Master Combination is a six-digit combination used to reset the lock to the
factory default combination (50 25 50) in the event the user combination(s) are lost. See
the Super Master Operations sheet (P/N 3001.032).
LOCK MODES
A maximum of two users can exist in a lock. A lock can operate in either Single Mode or
Dual Custody Mode.
Note:
For a UL listed installation, only one user can be activated.
• Single Mode
Single Mode defaults to having only a Manager User (User 1) in the lock. A second
user (User 2) can then be added by the Manager User (User 1). (See section on
Manager User Operations.)
In Single Mode only one valid user combination is required to open the lock - the Manager
User (User 1) combination or the User 2 combination.
Note: Default lock status from the factory is Single Mode with an opening
combination of "50 25 50" for the Manager User (User 1).
Dual Custody Mode
Dual Custody Mode defaults to two users in the lock - User 1 and User 2.
Two user combinations are required to open the lock - the User 1 combination and the
User 2 combination.
Note: Manager User Operations are not available in Dual Custody Mode.

Advertisement

Table of Contents
loading

Summary of Contents for Kaba 52

  • Page 1 PERATING NSTRUCTIONS The following instructions cover Model 52 & T52 lock operations. The lock models operate the same except for an additional feature that is found in the Model T52 that allows you to program a time delay for lock opening and an opening window for the lock.
  • Page 2 LOCK OPERATION & RESPONSES • To “power” a self-powered lock, turn the dial back and forth in both directions. • The lock is “powered” when simultaneous green and red flashes display with a beep • Each keystroke generates a green flash with a beep •...
  • Page 3 CHANGE COMBINATION WARNING: Super Master Control will be permanently lost if you do not change the default Super Master Combination prior to changing any User combinations. See Super Master Operations sheet (P/N 3001.032). Caution: Before changing combination, open the container door to allow testing with the new combination.
  • Page 4: Battery Assist

    SET DELAY TIME AND OPENING WINDOW* * This feature is only available on the Model T52 lock. For self-powered lock, power the lock Press . Press • For Single Mode (Factory combination is “50 25 50”.) Enter Manager User (User 1) combination. •...
  • Page 5: Delete User

    Manager User Operations These operations are only available in Single Mode and can only be performed by the Manager User (User 1). All Manager User Operations involve management of User 2. User 2 can have a lock access status of “Enabled” or “Disabled”. If “Enabled”, User 2 can open the lock.
  • Page 6: Replace Battery

    Battery Maintenance The battery must be maintained for both Battery powered locks and Battery Assist locks. REPLACE BATTERY Enter a valid combination and open the lock. Note: For a Battery powered lock if the existing battery will not provide enough power for you to open the lock, hold a fresh 9 Volt Alkaline Battery to the lock with the contacts touching the metal trim encircling the red and green LEDs.
  • Page 7 OTES...
  • Page 8 Document Number 3002.032 Rev. C - 04/03 Kaba Mas Corporation 749 W. Short Street, Lexington, KY 40508 USA Phone: (859) 253-4744 FAX: (859) 255-2655 Technical Support: (800) 950-4744 www.kaba-mas.com...

This manual is also suitable for:

T52

Table of Contents