2. Using a #2 Phillips screwdriver, remove the four screws from the rails (two
screws in each rail). See 4 in Figure 13 on page 32. If you do not remove
these screws, the storage subsystem will not fit securely.
Note: If the screws are shipped in the hardware pack instead of already
installed in the rails, skip this step and go to step 3.
3. Place the storage subsystem in the rack.
Note: If you have removed the CRUs from the DS4200 Express, you should be
able to lift the unit into the cabinet with the help of one other person. If
you have not removed the CRUs before the installation, you should have
at least two other people available to help you lift the DS4200 Express
into the rack.
a. Move the storage subsystem to the front of the rackmount cabinet.
b. With help from another person, place the back of the storage subsystem on
the support rails, and then slide the unit into the rack as shown in Figure 17.
Front of Rack
Figure 17. Installing the DS4200 Express
4. Secure the storage subsystem. Figure 18 on page 38 shows how to secure the
storage subsystem to the rack.
a. Align the front mounting holes on each side of the storage subsystem with
the mounting holes on the front of the support rails.
b. Using the screws that you removed in step 2, secure the sides in the back
of the DS4200 Express to the rack rails.
c. Secure the front of the DS4200 Express using the four M5 screws as shown
in Figure 18 on page 38.
Chapter 2. Installing the storage subsystem
37