For Home Owners
2
In order to get the ultimate benefit from your heat pump FIGHTER 1220 you should read through
the For Home Owners section in this Installation and Maintenance Instruction.
FIGHTER 1220 is a heat pump central for the production of heating and domestic hot water in detached
and terrace houses. The ground, rock or lakes can be used as the heat source.
FIGHTER 1220 is a Swedish made quality product offering a long life span and safe operation.
Completedby the installer when the heat pump is installed
,
The serial number (95)
correspondence with NIBE.
689_ _ _ _ _ _ _ _ _ _
FIGHTER 1220-_ _ kW
Installation date
Anti-corrosion
Enamel
Installation engineers
The type of brine — Mixing proportion/freezing point
Active drilling depth/collector length
Commissioning checks
Temperature brine (flow/return)____ / ____
(Nominal temperature diff 2 - 5 °C)
Temperature heat medium (in/out)
(Nominal temperature diff 5 - 10 °C)
Settings
Menu
1.4 Start temp. HW ............ 47
1.5 Stop temp. HW.............. 54
1.6 Stop temp. XHW.............. 60
1.8 XHW interval
.............. 14
2.0 Flow temperature ........ 47
2.1 Curve slope
.............. 5
2.2 Offset. heating curve .... 5
2.3 Supply temp/MIN ............ 15
2.4 Supply temp/MAX............ 55
Date ________Signed ______________________________

General

should always be stated with all
Stainless steel
Pump setting
____ / ____
Pump setting
Basic
Position
setting
100 "Fuse"
101 "Max electrical output"...... C
102 "Max boiler temp" ............ 65
FIGHTER 1220
Copper
___
___
Basic
setting
........
20