Tactile Modules - Siemens ST750 Configuration Handbook

Controller configuration handbook 667/cc/32750/000
Hide thumbs Also See for ST750:
Table of Contents

Advertisement

Figure 48 the additional Audible Driver Supply Kit should fitted in the position allocated to the
Loop Termination PCB LT5. Loop Termination PCBs occupying Loop Termination position LT5
and greater should be incremented by one position.
Note: A Dual Pelican configuration does not normally operate with audibles.

Tactile Modules

3.14
The ST750ELV controller can be fitted with either switched or non-switched tactiles. Non-
switched tactiles are wired directly across the pedestrian green terminals, marked 'TACT', and
shown in Figure 55.
Switched and non-switched tactiles can be driven in parallel from each of the TACT outputs and
from the Audible Drive output 'ADRV'. Limitations on number of tactiles that can be driven from
the two TACT outputs and the ADRV output should be sought from ST750ELV Handbook
(667/HB/32750/000).
Security classification
Version
Last Editor
Document Name
Copyright © Mobility 2017. All Rights Reserved.
Figure 55
Error! Unknown document
property name.
008
Nathan Fearnhead
Configuration Control
Mobility is a division of Siemens Plc
Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
Tactile and
Audible
Driver
Connections
47 of 73
Page
Released
Status
16/06/2017
Date
667/CC/32750/000
Document No.

Hide quick links: