Dear consumer,
thank you for purchasing the heat pump Neore. We hope you will be satisfied with the device which shall bring
heat comfort to your house.The pump is a quite complicated device therefore pay high attention to this manual,
please. The manual shall make you familiar with using, placement, construction and further information.

IMPORTANT NOTICE

The heat pump Neore in intended for reduced electricity rates for heat pumps (czech d56) or for convector
heating rate (czech d46).A permission of an appropriate distributor has to be obtained before connecting to the
energy grid.Only authorized company is allowed to carry out installation, connecting, and service. The warranty
card is not valid without authorization.
1.COMPLETENESS
The Neoré heat pump is a split type.
Indoor unit: IO 16 -15 Neoré
Outdoor unit: AOYG....., WOYK.....
Outdoor temperature sensor
DHW temperature sensor
User manual
Warraty card

2.APPLICATION

Heat pumps Neore are intended for heating of houses or small industrial buildings. The product shall be
connected to low-temperature heating system, such as floor heating, wall or ceiling heating. Connecting of wall
heating convectors is possible but maximum temperature of heating water is limited to 50 °C. (60 °C at type HP)
However, efficiency is worse at this temperature (COP decreases). Heat pump can be also used for cooling.
At cooling mode is output water temperature limited to condensing temperature. Heat pump is not suitable for
cooling with water temperature under condensing temperature e.g. fancoil. Low temperature water causes
condensation on inner equipment of indoor unit and thereby the damage. Suitable cooling system cooling ceiling,
where condensation does not occur.

3. PRODUCT DESCRIPTION

Basic construction elements:
- Outdoor unit
It is made from a steel tin with anti-rust treatment which is reached by a powder varnish. Its heart is made by
inverted double level compressor which is a novelty in the field of heat pumps guaranteeing reliability and
longevity. The unit also contains an exchanger with anti-rust treatment and 30 years lifetime, fans with variable
revolutions, electronic expansion valve, controlling and measuring elements.
- Indoor unit
Its main part is a board heat exchanger refrigerant / water. Another substantial part is TECO regulator with
sophisticated software which controls operation of the pump and also controls temperature in the building. The
regulator provides cascade regulation of the heat pump with bivalent supply. There is also a possibility to connect
to the PC via web interface for comfortable and effective control of the heat pump. The unit also contains
protecting, measuring and regulation elements.