QUICK SETUP

Descriptions of the controls
Object section
Displays mode of
heating / cooling, object temp.,
circulator state, object state,
main switch operation
heating / cooling
DHW section
Displays temp. of DHW, DHW
circulator state,
heating state,
main switch DHW heating
Basic controls:
For basic controls of the heat pump use graphical touch panel.
Main menu (press button „MENU")
Main screen - summmary. Used for switch on / off Heat pump, DHW heating.
Displays the overview of most important values and allows entry to states and
errors screen (button More... → State, errors) and entry to screen of supplied
power measure (button More... → Calorimeter)
Heating / cooling parameters settings. This section allows to set equithermic
curve, attenuation, follow energy tariff for heating / cooling, required
temperature of object, bivalent source state and more...
DHW heating parameter settings. This section allows set temperature of DHW,
heating and circulation time schedule, follow energy tariff for DHW heating,
bivalent source state and more...
Elements on display, which are possible to change values, switch ON/OFF or refer to next screen have got orange underlay. After
pressing element is either displayed refered screen or is displayed panel for variable adjustment. Appearence of panel depends
on type of variable.
Winter operation with DHW
On the main screen
corner) . In settings
For 200l water tank set 40min, 300l - 60min, 400l - 90min. Equithermal curve in section
case of radiators T - at -20°C to 50°C, T - at -8°C to 45°C, T - at +5°C to 40°C, T - at +15°C to 35°C,
and in the case of floor heating T - at -20°C to 40°C, T - at -8°C to 35°C, T - at +5°C to 30°C, T - at +15°C to 25°C.
Then adapt your required temperature by automatic correction of equithermal curve.
Winter operation without DHW
On the main screen
the case of „Winter operation without DHW".
In heated rooms are cold or too warm
For example, if the room temperature is 2 degrees higher than required, enter the automatic correction eq. curve
in object section to -3°C. When the difference in room temperature eg about 1°C lower than required, enter the
correction + 2°C and so on. The maximum correction is +/- 3°C for one insertion. Remember that change takes
effect after a certain time. For floor heating be aware of delays thermal exchanges in the rooms due to changes in
water temperature 3-6 hrs.
The upper bar displays time, successfully connected Neoré Route (cloud)
service and Ethernet connection.
set icon
and
set the required DHW temperature and delays of the DHW electric heating.
set icon
to ON and icon
Graphs of important values
Outdoor unit temperature, object temperature, output water temperature,
DHW temperature, required output power.
Expanded parameter settings of heat pump. This section allows to set maximal
power of outdoor unit, cooling parameters, Ethernet network settings
and more...
Nastavení
This section allows to set parameters of pool heating ande using of secondary
source
to ON (orange colored rectangle in upper right
to OFF . Equithermal curve pre-set as in
1
Overview section
Displays important
temperatures and paremeters,
operation states, outdoor unit
power, icon of economic
operation, access to main
menu and expanded overview,
whitch contains error history,
measure of supplied power
and more ...
pre-set in the