FIFOTRACK A500 User Manual page 16

3g vehicle gps tracker
Table of Contents

Advertisement

A500 USER GUIDE
VCC
IN2
GND
IN1
I/O
Color
VCC
Red
GND
Black
IN2
White
IN1
White
IN4
White
IN3
White
OUT2
Yellow
OUT1
Yellow
AD2
Blue
AD1
Blue
Copyright © fifotrack 2015 All rights reserved
IN4
OUT2
IN3
OUT1
Function
Positive power, connect to positive of vehicle battery, input voltage range
11-36V
GND, connect to negative of vehicle battery or the vehicle's iron part.
Digital input2, positive input, default connect to ACC for status detection.
Digital input1, negative input (default SOS button)
Digital input4, custom input, default negative.
Digital input3, custom input, default positive.
Output2
Output active: low level (0V)
Output inactive: open drain (OD)
Max open-drain (inactive) voltage: 45V
Max current for output low voltage (valid): 500mA
Output1
Output active: low level (0V)
Output inactive: open drain (OD)
Max open-drain (inactive) voltage: 45V
Max current for output low voltage (valid): 500mA
12 bits analog input, supports voltage range 0-12V. Connect to external
sensor, e.g., fuel sensor.
12 bits analog input, supports voltage range 0-6V. Connect to external
sensor, e.g., fuel sensor.
AD2
PLS
AD1
iBtn
DC5V
GND
16