Mirage Reinigungstechnik
• Check the status of the motor brush on every engine, if worn, proceed
with the replacement as described in paragraph "Maintanance of
suction motor"
Every Year
• Check the safety devices and their functionality.
• Check the electrical system: Possible defects such as loose
connections or scorched cables, must be rectified immediately.
In addition to those described in the above table, the machine requires specific maintenance operations
indicated in the following paragraphs.
18.4
WATER FILTER CLEANING / REPLACEMENT
Unscrew the filter placed below the clean water tank, present in the connecting pipe with the rotary brush
(ref 2, Figure 2).
With reference to the FKC 46:
Take out the filter from the water circuit
(encircled in the figure below)
Blowing it with an air jet and then screw it
again, by interposing the sealing ring of which
the filter is provided
ATTENTION!
18.5

SOLENOID VALVE CLEANING

1. Proceed by disconnecting the connectors of the electrical connections present on the upper part
of the solenoid positioned as in figure:
FKC 46
the brush motor
_____________________________________________________________________________________
LIBRETTO USO E MANUTENZIONE
The cleaning / replacement of the water filter should be more frequent in the case of
using ferrous water.
internal compartment adjacent to
With reference to the FKC 36:
• After removing the 2 tanks,
• Unhook from both ends the circuit where it
passes through the wash water
• Replace the disposable filter (encircled in
the figure below), then place the new filter
and close the circuit as shown in the figure
below,
FKC 36
under the white derivation box
inside the machine
pagina 25