Supermicro SuperWorkstation 5039D-I User Manual

Supermicro SuperWorkstation 5039D-I User Manual

Lga 1151

Advertisement

Quick Links

The information in this User's Manual has been carefully reviewed and is believed to be accurate. The vendor assumes
no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update
or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note:
For the most up-to-date version of this manual, please see our website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual
at any time and without notice. This product, including software and documentation, is the property of Supermicro and/
or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except
as expressly permitted by the terms of said license.
IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT
OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER
MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED
OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING,
INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
SuperWorkstation
®
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the
State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution
5039D-I
of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the manufacturer's instruction manual,
may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only
to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate".
WARNING: Handling of lead solder materials used in this product may expose you to lead, a
chemical known to the State of California to cause birth defects and other reproductive harm.
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment,
nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical
systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products
for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully
indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Manual Revision 1.0
Release Date: December 02, 2015
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this
document. Information in this document is subject to change without notice. Other products and companies referred
to herein are trademarks or registered trademarks of their respective companies or mark holders.
USER'S MANUAL
Copyright © 2015 by Super Micro Computer, Inc.
All rights reserved.
Revision 1.0
Printed in the United States of America
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SuperWorkstation 5039D-I and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro SuperWorkstation 5039D-I

  • Page 1 5039D-I of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product. FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
  • Page 2: Table Of Contents

    This manual is written for professional system integrators and PC technicians. It provides 1.3 System Specifications ......................9 information for the installation and use of the SuperWorkstation 5039D-I. Installation and maintainance should be performed by experienced technicians only. 1.4 Server Chassis Features ....................10 Please refer to the 5039D-I specifications page on our website for updates on supported Control Panel ........................10...
  • Page 3 SuperWorkstation 5039D-I User's Manual Preface Contacting Supermicro Chapter 4 Motherboard Connections 4.1 Power Connections ......................33 4.2 Headers and Connectors ....................34 Headquarters Control Panel .........................39 Address: Super Micro Computer, Inc. Data Cables ........................42 980 Rock Ave. San Jose, CA 95131 U.S.A.
  • Page 4: Overview

    Internal 3.5" HDD Drive Trays MCP-220-73101-0B 1.2 Unpacking the System Inspect the box the SuperWorkstation 5039D-I was shipped in and note if it was damaged in any way. If any equipment appears damaged, please file a damage claim with the carrier who delivered it.
  • Page 5: System Specifications

    SuperWorkstation 5039D-I User's Manual Chapter 1: Introduction 1.3 System Specifications 1.4 System Chassis Features The following table provides you with an overview of the main features and specifications of the 5039D-I. Please refer to Appendix C for additional specifications. Control Panel The switches and LEDs located on the control panel are described below.
  • Page 6: Front Features

    SuperWorkstation 5039D-I User's Manual Chapter 1: Introduction Front Features Rear Features The SC731i-300B is a mini-tower chassis. See the illustration below for the features included The illustration below shows the features included on the rear of the chassis. on the front of the chassis.
  • Page 7: Motherboard Layout

    SuperWorkstation 5039D-I User's Manual Chapter 1: Introduction 1.5 Motherboard Layout Quick Reference Table Below is a layout of the X11SSL-F with jumper, connector and LED locations shown. See the Jumper Description Default Setting table on the following page for descriptions. For detailed descriptions, pinout information and...
  • Page 8 SuperWorkstation 5039D-I User's Manual Chapter 1: Introduction #A-2 #A-1 IMVP 8 Connector Description 3 PHASE for Vcore #B-2 PCI-E (PCH) Slot 5 PCI-Express 3.0 x4 in x8 Slot #B-1 PCI-E X8 Gen3 PCIe3.0 x8 (in x8) #8-15 Internal Speaker/Buzzer Skt-H4...
  • Page 9: Chapter 2 Workstation Setup

    SuperWorkstation 5039D-I User's Manual Chapter 2 Workstation Setup 2.1 Overview This chapter provides advice setting up your system. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components.
  • Page 10: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 11: Motherboard Components

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Installing the Processor(s) Begin by removing power from the system as described in Section 3.1.
  • Page 12 SuperWorkstation 5039D-I User's Manual Chapter 3: Maintenance and Component Installation Screw#2 Screw#1 Figure 3-4. Inspecting the Processor Installation Motherboard 5. With the processor inserted into the socket, inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket.
  • Page 13: Memory Installation

    Reapply the proper amount of thermal grease to the surface before you re-install the Release Tabs heatsink. Figure 3-8. Installing DIMMs Note: Wait for the heatsink to cool down before removing it. Note: Visit the product page on the Supermicro website for possible updates to memory support (www.supermicro.com).
  • Page 14: Dimm Module Population Sequence

    SuperWorkstation 5039D-I User's Manual Chapter 3: Maintenance and Component Installation DIMM Module Population Sequence PCI Expansion Card Installation When installing memory modules, the DIMM slots should be populated in the following order: Three standard size PCI expansion (add-on) cards may be installed in the system.
  • Page 15: Chassis Components

    8. If desired, each hard drive may be further secured to the drive cage with an additional (optional) screw at the middle of the drive.) Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www.
  • Page 16: Optional Drive Bays

    SuperWorkstation 5039D-I User's Manual Chapter 3: Maintenance and Component Installation Optional Drive Bays System Cooling The SC731i-300B chassis has two empty 5.25" drive bays that support optional devices such The SC731i-300B includes a super quiet rear system fan that provides cooling for the chassis.
  • Page 17: Power Supply

    SuperWorkstation 5039D-I User's Manual Power Supply The 5039D-I chassis includes a 300-watt power supply. The power supply has the capability to automatically sense and operate with an input voltage of 100 or 240V AC. If it becomes necessary to replace the power supply, follow the instructions below.
  • Page 18: Chapter 4 Motherboard Connections

    SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections Chapter 4 4.2 Headers and Connectors Fan Headers There are five fan headers on the motherboard. These are 4-pin fan headers; pins 1-3 are Motherboard Connections backward compatible with traditional 3-pin fans. The onboard fan speeds are controlled by Thermal Management via IPMI.
  • Page 19 SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections TPM/Port 80 Header Power LED/Speaker A Trusted Platform Module (TPM)/Port 80 header is located at JTPM1 to provide TPM support Pins 1-3 of JD1 are used for power LED indication and pins 4-7 are for the speaker. Please note that the speaker connector pins (4-7) are used with an external speaker.
  • Page 20 Pin# Definition Data Note: UID can also be triggered via IPMI on the motherboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. Clock UID Switch UID LED Pin Definitions...
  • Page 21: Control Panel

    SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections Control Panel Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset JF1 contains header pins for various control panel connections. See the figure below for the switch on the computer case.
  • Page 22: Data Cables

    SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections NIC1/NIC2 (LAN1/LAN2) NMI Button The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 The non-maskable interrupt button header is located on pins 19 and 20 of JF1.
  • Page 23: Ports

    The X11SSL-F includes a total of six SATA ports, supported by the Intel C232 PCH chip. These SATA ports support RAID 0, 1, 5, and 10. Back Panel USB 0/1 (USB 2.0) Front Panel USB 2/3, 4/5 (USB 2.0) Notes: I-SATA0 and I-SATA1 are Supermicro SuperDOMs. These are yellow SATADOM ports Pin Definitions Pin Definitions Pin#...
  • Page 24: Jumpers

    SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections VGA Port CMOS Clear A video (VGA) port is located next to LAN2 on the I/O back panel. JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.
  • Page 25 SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections LAN1/2 Enable/Disable BIOS Recovery Change the setting of jumper JPL1 and JPL2 to enable or disable the LAN1 and LAN2 Use jumper JBR1 to recover the BIOS settings on the motherboard. The default setting is Ethernets ports, respectively.
  • Page 26: Led Indicators

    SuperWorkstation 5039D-I User's Manual Chapter 4: Motherboard Connections 4.5 LED Indicators BMC Heartbeat LED A BMC Heartbeat LED is located at LEDBMC on the motherboard. When LEDBMC is blinking, the BMC is functioning normally. LAN LEDs Two LAN ports are located on the rear I/O panel of the motherboard. Each Ethernet LAN Onboard Power LED Indicator port has two LEDs.
  • Page 27: Chapter 5 Software

    SuperWorkstation 5039D-I User's Manual Chapter 5: Software Chapter 5 5.2 Driver Installation The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro. com. Some of these must be installed, such as the chipset driver. Software After accessing the FTP site, go into the CDR_Images directory and locate the ISO file for your motherboard.
  • Page 28: Superdoctor

    5.4 IPMI ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based The X11SSL-F support the Inteliigent Platform Management Interface (IPMI). IPMI is used to interface for Windows and Linux operating systems. The program monitors such system health provide remote access, monitoring and management.
  • Page 29: Chapter 6 Bios

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Chapter 6 6.2 Main Setup When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen.
  • Page 30: Advanced Setup Configurations

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS 6.3 A dvanced Setup Configurations Memory Information Total Memory Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items. This item displays the total size of memory available in the system.
  • Page 31 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Wait For 'F1' If Error CPU Configuration Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs. The following CPU information will display: The options are Disabled and Enabled.
  • Page 32 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Active Processor Cores Package Power Limit MSR Lock This feature determines how many CPU cores will be activated for each CPU. When all Select Enabled to lock the package power limit for the model specific registers. The options is selected, all cores in the CPU will be activated.
  • Page 33 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS C-State Auto Demotion Chipset Configuration Use this feature to prevent unnecessary excursions into the C-states to improve latency. The Warning: Setting the wrong values in the following features may cause the system to malfunc- options are Disabled, C1, C3, and C1 and C3.
  • Page 34 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS CPU SLOT7 PCI-E 3.0 X8 DMI/OPI Configuration SLOT7 Max Link Speed The following DMI information will display: Use this item to configure the link speed of a PCI-E port specified by the user. The options •...
  • Page 35 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Maximum Memory Frequency PCI Express Configuration Use this feature to set the maximum memory frequency for onboard memory modules. The DMI Link ASPM Control options are Auto, 1067, 1200, 1333, 1400, 1600, 1800, 1867, 2000, 2133, 2200, and 2400.
  • Page 36 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS SLOT5 PCIe Speed Port 0 ~ Port 7 Spin Up Device (Port 6 and Port 7 on X11SSM-F only) Use this feature to select the PCI Express port speed. The options are Auto, Gen1, Gen2, On an edge detect from 0 to 1, set this item to allow the PCH to initialize the device.
  • Page 37 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS CPU SLOT 7 PCI-E 3.0 X8 OPROM Super IO Configuration Use this feature to select which firmware type to be loaded for the add-on card in this slot. The following Super IO information will display: The options are Disabled, Legacy, and EFI.
  • Page 38 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Serial Port 2 Change Settings COM1 Console Redirection Settings This feature specifies the base I/O port address and the Interrupt Request address of a serial This feature allows the user to specify how the host computer will exchange data with the port specified by the user.
  • Page 39 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS COM1 Recorder Mode COM2 Bits Per second Select Enabled to capture the data displayed on a terminal and send it as text messages to Use this feature to set the transmission speed for a serial port used in Console Redirection.
  • Page 40 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS COM2 Putty KeyPad Flow Control This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator Use this item to set the flow control for Console Redirection to prevent data loss caused by designed for the Windows OS.
  • Page 41 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS iSCSi Configuration Trusted Computing Configuration   iSCSI Initiator Name Security Device Support This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format. If this feature and the TPM jumper on the motherboard are both set to Enabled, onbaord...
  • Page 42 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS PCI Device ID Device Name This item displays the device ID number. This item displays the adapter device name. PCI Address Chip Type This item displays the PCI address for this computer. PCI addresses are 3 two-digit This item displays the network adapter chipset name.
  • Page 43: Event Logs

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS 6.4 Event Logs SMBIOS Event Long Standard Settings Log System Boot Event Use this feature to configure Event Log settings. This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled.
  • Page 44: Ipmi

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS 6.5 IPMI When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log Use this feature to configure Intelligent Platform Management Interface (IPMI) settings.
  • Page 45: Security

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Station MAC Address 6.6 Security This item displays the Station MAC address for this computer. Mac addresses are 6 two-digit This menu allows the user to configure the following security settings for the system.
  • Page 46 SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS Secure Boot Mode Append Key Use this item to select the secure boot mode. The options are Standard and Custom. Select Yes to add the database from the manufacturer's defaults to the existing DB. Select No to load the DB from a file.
  • Page 47: Boot

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS 6.7 Boot • Legacy/UEFI/Dual/Boot Order #8 Use this feature to configure Boot Settings: • Legacy/UEFI/Dual/Boot Order #9 • Legacy/UEFI/Dual/Boot Order #10 • Legacy/UEFI/Dual/Boot Order #11 • Legacy/UEFI/Dual/Boot Order #12 • Legacy/UEFI/Dual/Boot Order #13 •...
  • Page 48: Save & Exit

    SuperWorkstation 5039D-I User's Manual Chapter 6: BIOS 6.8 Save & Exit Default Options Select the Exit tab from the BIOS setup utility screen to enter the Exit BIOS Setup screen. Restore Optimized Defaults To set this feature, select Restore Optimized Defaults from the Save & Exit menu and press <Enter>.
  • Page 49: Appendix A Bios Error Codes

    When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). A-1 BIOS Error Beep (POST) Codes For information on AMI updates, please refer to http://www.ami.com/products/.
  • Page 50: Appendix B Standardized Warning Statements For Ac Systems

    Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de Read this appendix in its entirety before installing or configuring components in the Supermicro manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese chassis.
  • Page 51 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements Warnung ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬...
  • Page 52 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements Power Disconnection Warning Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Warning! The system must be disconnected from all sources of power and the power Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung cord removed from the power supply module(s) before accessing the chassis interior nicht mehr als: 250 V, 20 A beträgt.
  • Page 53 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements Attention ‫امداد‬ ‫وحدة‬ ‫من‬ ‫سهك انكهرباء‬ ‫وإزانت‬ ‫انطاقت‬ ‫مصادر‬ ‫من جميع‬ ‫اننظاو‬ ‫يجب فصم‬ Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés.
  • Page 54 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements Battery Handling Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace sonstigen Sicherheitsvorkehrung möglich.
  • Page 55 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements ¡Advertencia! ‫فعليل‬ ‫بطريقة غير صحيحة‬ ‫البطارية‬ ‫انفجار في حالة اسحبذال‬ ‫من‬ ‫هناك خطر‬ Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar ‫اسحبذال البطارية‬ por completo el suministro de energía, deben desconectarse todas las conexiones.
  • Page 56 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements Backplane Voltage ‫اللىحة‬ ‫أوالطاقة المىجىدة على‬ ‫التيار الكهزبائي‬ ‫مه‬ ‫خطز‬ ‫هناك‬ ‫هذا الجهاس‬ ‫خدمة‬ ‫كه حذرا عند‬ ‫يعمل‬ ‫النظام‬ ‫عندما يكىن‬ Warning! Hazardous voltage or energy is present on the backplane when the system is operating.
  • Page 57 SuperWorkstation 5039D-I User's Manual Appendix B: Standardized Warning Statements ‫תיאום חוקי החשמל הארצי‬ Attention !‫אזהרה‬ La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬...
  • Page 58 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 Verwendung von UL-oder CSA-zertifizierte Kabel, UL oder CSA auf der Code für alle anderen 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이 가까이 하지 elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben. 않도록 배치해 주십시오. Waarschuwing ¡Advertencia!
  • Page 59 Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand. Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen.
  • Page 60: Appendix C System Specifications

    SuperWorkstation 5039D-I User's Manual Appendix C: System Specifications Appendix C Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,...