Depth gauge setting
The depth gauge determines the
thickness of the chip removed.
Specified distance between depth
gauge and cutting edge:
a = 0.026 in (0.65 mm)
Lowering depth gauges
The depth gauge setting is reduced
when the chain is sharpened.
:
Check setting every time you
sharpen the chain and, if necessary,
lower the depth gauges with the
USG universal sharpener.
56
Settings on USG sharpener
+
a
A
-
36 RDR saw chain
Cutter
right
left
A
+10
+10
B
0
C
+15
-15
+
-
C
-
+
B
Depth gauge
+40
0
0
0
After sharpening
:
Clean the chain thoroughly, remove
filings or grinding dust – lubricate
the chain thoroughly.
:
Before long out-of-service period,
clean the chain and store it in a
well-oiled condition
Repairs
The saw chain can be repaired with tools
NG 3, NG 4, NG 5 and NG 7.
Chain breaking and riveting is possible
at the cutters, tie straps, triple-humped
tie straps and drive links of 36 RDR
chain.