3-2 ASSY CONTROL BOX
WARNING
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
the range. Replace all panels before operating range. Failure to do so can result in death or personal
CAUTION
When you work on the gas range, be careful when handling sheet metal parts. Sharp edges may be
present, and you can cut yourself if you are not careful.
Explanation Photo
2
2
2
2
2
3
3
Disconnect the wire
Assy Wire A
17
Explanation
1. Remove 6 Knobs from the Assy Control
Box.
2. Remove 2 screws from the each 5 Holder
Knobs except for Holder Knob Warmer.
3
3. Open the Door and Remove 4 screws
from the bottom of Assy Control Box.
4. Lift the Assy Control Box slightly to
separate from the range.
is still connected to the Assy Display of
5. Disconnect 3 wire connectors from the
6. Remove the Assy Control Box from the
range.
Wire Main