5. Service Tables
CERT: Issuer
5816 092
Displays the common name of the issuer of the NRS certification. CN = the following 30
bytes. Asteriskes () indicate that no DESS exists.
CERT: St ExpTime
5816 093
Displays the start time of the period for which the current NRS certification is enabled.
CERT: End ExpTime
5816 094
Displays the end time of the period for which the current NRS certification is enabled.
Poling Man Exc
5816 200
No information is available at this time.
5
Instl: Condition
Displays a number that indicates the status of the NRS service device.
0: Neither the NRS device nor Cumin device are set.
1: The Cumin device is being set. Only Box registration is completed. In this status the
5816 201
Basil unit cannot answer a polling request.
2: The Cumin device is set. In this status the Basil unit cannot answer a polling request.
3: The NRS device is being set. In this status the Cumin device cannot be set.
4: The NRS module has not started.
Instl: ID #
5816 202
Allows entry of the number of the request needed for the Cumin device.
Instl: Reference
5816 203
Executes the inquiry request to the NRS GW URL.
Instl: Ref Rslt
Displays a number that indicates the result of the inquiry executed with SP5816-203.
0: Succeeded
1: Inquiry number error
5816 204
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)