OSD Menu Setting
I-2. PATT TITLE
On working PATTERN, the function for inputting the characters for title if
showed up on the screen.
- Default os for "PATTERN01 □□□□□□□"
- The changing of character can be set up using the Left/Right/Up or Zoom
In/Out of joystick.
I-3. DATA FILL
This is for marking when saving or status of PATTERN DATA.
- If you press the Focus Far Key, "DATA FILL" would be blinked and get started
saving of Manual value. In this time, if data saved by 99%, Cursor could be
placed on the save automatically after stop the operation.
- Blinking of DATA FILL would be stopped and DATA saved on the right
would be signed to "%" if you press the Focus Far Key after Manual
adjustment is finished.
I-4. SAVE
This is for saving the data set and in case saving the value, Cursor would be
moving on PATT NO and the value of NO grows up each 1.
I-5. EXIT
It is used to take off the PATTERN SET MENU.
J. ALARM
You can get the function in using Left/Right of Joystick after ALARM in Main
Menu and it makes it operating special when it senses the changing the 4ports
inside.
ALARM NO.
ALARM INPUT
ALARM ACT
AUX ACT
SAVE
EXIT
J-1. ALARM NO.
It can be chosen the ALARM number that you'll set .
PTZ CAMERA
ALARM SET
: 01
: OFF
: 001
: BLK
030
OSD Menu Setting
J-2. ALARM INPUT
Set up the sensing way of ALARM or Using ARARM.
- [OFF/NO/NC] can be set up.
- NO's meaning is Normal Open and handle the CLOSE to NORMAL of OPEN.
- NC's meaning is Normal Close and handle the OPEN to NORMAL of CLOSE.
- It should be controlled by using LEFT/RIGHT of Joystick.
J-3. ALARM ACT
This is for registration the operating when occur ALARM.
- The number of registration for PRESET is [1..64, 100..200]/TOUR[01..08]/
PATTERN[01..08]
- PRESET is marked with 3words and changed to ([001..064], [100..200])
automatically.
- TOUR is marked with 3words of [P01...P08]. Each PATTERN is YOUR[1...8].
- PATTERN is marked with 3wordsof [T01...T08]. Each is TOUR[1..8].
- In case of PRESET, ACTION is over after completion of moving for PRESET
position.
- In case of TOUR/PATTERN, ACTION is over after completion each 1 time.
J-4. AUX ACT
On occurrence ALARM, it's function for controlling the outdoor PORT.
- You can choice between BLK/AUX1/AUX2
- When setting to BLK, on occurrence the ALARM, There's no changing AUX
terminal.
- On setting AUX1, it should handle the terminal into on when occurrence

ALARM.

- On setting AUX2, it should handle the terminal into on when occurrence
ALARM.
- The holding time for ON of each AUX terminal is fasten 5sec.
J-5. SAVE
This is for saving the set value, NO is raised up 1, when Cursor places to
ALARM NO.
J-6. EXIT
This is used to take off the ALARM MENU.