4-5Maintenance parts replacement procedures (option)

(1) Paper feeder
(1-1)Detaching and reattaching the PF main PWB
Procedures
1. Remove two screws(M3×8P tight)(a).
2. Release two hooks (b) of the upper
cover (c) and detach it.
3. Disconnect all the connectors (a) from
the PF main PWB(c).
4. Remove three screws(M3×8P tight)(b).
5. Detach the PF main PWB (c).
6. Check the status of the PF main PWB
(c), clean or replace it as needed.
7. Reattach the parts in the original posi-
tion.
a
b
Figure 4-158
Figure 4-159
4-87
2RV/2RW/2RX/2RY/3RA
a
c
b
b
a
c