Page 1
WOOD Fireplace Insert & Hearth Heater Owners & Installation Manual www.regency-fire.com MODELS: H2105 I3105L Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.
Page 2
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.
Optional Flue Connector Kit ..........7 Door Gasket ..............15 Masonry and Factory Built Fireplace Clearances ..7 Door Latch Adjustment ..........15 Leg Option on H2105 Hearth Heater ......8 Glass Cleaning ............15 Flue Connector Bracket ..........8 Glass Replacement .............15 Installation Into a Factory Built Fireplace.......8 Glass Removal ............15...
This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Large Flush Insert. We have printed improved. Check the label on the unit and if a copy of the contents here for your review.
This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Hearth Heater. We have printed a improved. Check the label on the unit and if copy of the contents here for your review.
Install and use jurisdiction. only in accordance with manufacturer’s installation and operating instructions. Regency Inserts are designed to use either a 5.5" (140mm) or 6" (152mm) flue. FIREPLACE 2) Check your local building codes - Building Inspection Department.
18" (450 mm) in Canada to the front of the unit and Clearance diagram for installations 8" (200 mm) to the sides. If the unit is not raised, thermal floor protection required is 18" (450 mm) in the US and Canada. Regency Wood Insert & Hearth Heater...
6) Once the above items have been checked, slide your insert into position after first po- sitioning the flue liner and offset if required. (Re-install raincap at completion of installa- tion). Diagram 1: H2105M and I3105L Faceplate Assembly Regency Wood Insert & Hearth Heater...
Page 10
To replace the deflector, loosen off both bolts and slide defector upward and out. Install new defector and hand tighten bolts. Ensure positive location of the defector prior to hand tightening. WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Regency Wood Insert & Hearth Heater...
To attach, follow the instructions provided ing controls. Wiring errors can with the fan 4) Push the Regency logo plate into the two cause improper and dangerous holes in the front bottom left corner of the 1) Align the fan support with the offset clip fan.
2) Tilt the first Baffle Brick down and then slide then replace them when cleaning is the 2nd Baffle Brick up and back. Reposition completed. both baffle bricks flat on the air tubes. Regency Wood Insert & Hearth Heater...
Overfiring will void your your draft will increase. side of fan housing to "Auto" and second switch warranty. to either "High" or "Low" for fan speed. The How to Light & Maintain a Wood Stove Fire Regency Wood Insert & Hearth Heater...
Removal of your insert for cleaning purposes is usually not required if a proper installation 7) Your Regency Insert can be very hot. You has been done. In the event that removal is re- The door latch may require adjustment as the...
Black Trim Oversize (Set of 3) 395) * Trim Right Oversize 396) * Trim Top Oversize 397) * Trim Left Oversize 398) * Faceplate Side Oversize 399) * Faceplate Top Oversize *Not available as a replacement part. Regency Wood Insert & Hearth Heater...
846-532 Trim Clips 30) * Grommet Strain Relief 836-300 Yellow Insulation 48" x 4" 846-531 Faceplate Hardware Pkg. 35) 120-954 Air Tube Front 36) 120-953 Air Tube Rear *Not available as a replacement part. Regency Wood Insert & Hearth Heater...
81) * Brick Partial: 1-1/4" x 1-1/4" x 9" 84) * Brick Partial: 1-1/4" x 4-1/2" x 8" 85) * Brick Partial: 1-1/4" x 4-1/4" x 8" * Not available as a replacement part Regency Wood Insert & Hearth Heater...
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
Page 22
WOOD Fireplace Insert www.regency-fire.com MANUEL D’INSTALLATION ET D’UTILISATION MODELS: I3105L Installateur : Remplissez la fiche de la couverture arrière et laissez ce manuel au propriétaire du foyer. Propriétaire du foyer : Conservez ces instructions pour référence ultérieure. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
Page 23
L’authorité ayant juridiction doit être consultée avant d’effectuer l’installation, pour déterminer si l’obtention d’un permis est nécessaire. Regency I3105...
Page 24
Optional Flue Connector Kit ..........7 Door Gasket ..............15 Masonry and Factory Built Fireplace Clearances ..7 Door Latch Adjustment ..........15 Leg Option on H2105 Hearth Heater ......8 Glass Cleaning ............15 Flue Connector Bracket ..........8 Glass Replacement .............15 Installation Into a Factory Built Fireplace.......8 Glass Removal ............15...
Page 25
Color: Everything printed black on grey except what is indicated as being printed in red. Dec. 16/14: Rev. C Updated ETL logo and manufacture dates Sept. 26/13:updated yrs. of manufacture. Apr. 7/11 Added. 5.5" stainless liner size Mar. 15/10: updated yrs. of manufacture. Jan. 2/08: updated yrs. of manufacture. Regency I3105...
Page 26
Colour: Black on grey, except for what is highlighted in yellow is red. Nov. 25/14: Updated ETL Logo Jan. 22/14: Updated yrs of manufacture Apr. 4/11:updated yrs. of manufacture / added 5.5" stainless liner Mar. 15/10: updated yrs. of manufacture. Jan. 2/08: updated yrs. of manufacture. Regency I3105...
Page 27
Plus vous comprendrez le fonctionnement de circulation de chaleur en métal). selon les normes du "Code du bâtiment" et de votre encastrable REGENCY plus vous serez "The standard for chimneys, fireplaces, vents en mesure de vous assurer qu’il vous donne 8) Retirer le conduit intérieur pour nettoyer la...
Page 28
Fixer les grilles à la paroi interne de l'appareil, de chaque côté, à l'aide de deux boulons, écrous View from Rear of Insert Remarque : Pour déterminer le sens de la grille, se fier à la découpe des trous, plate à l'arrière et arrondie à l'avant. Regency I3105...
Page 29
HEARTH HEATER The addition of legs to the Hearth Heater does not alter its certification, it does not become a freestanding woodstove. The H2105 can only be installed as a Hearth Heater i.e. vented into a masonry or factory built fireplace.
Page 30
6) Après avoir effectué ces vérifications, poser jusqu’au faîte de la cheminée. le conduit intérieur et le coude, s'il y a lieu, Regency recommande l’installation d’un conduit Installer l’appareil encastré conformément aux et glisser l'appareil en place. Remettre le intérieur complet pour une sécurité maximale et exigences du service d’inspection de votre...
Page 31
à cacher la bande isolante à l'arrière, en alignant ses ferrures de fixation au rebord des panneaux latéraux et à l'angle que forme le dessus de l'appareil. Compléter l'installation en fixant la garniture à la façade Faceplate Assembly Regency I3105...
Page 32
Pour remplacer le déflecteur, dévisser les deux boulons et le glisser vers le haut pour le dégager. Installer un nouveau déflecteur, vérifier sa position et resserrer les boulons à la main. AVERTISSEMENT : Un déflecteur mal installé annulera la garantie de l'appareil. Regency I3105...
Page 33
à la terre àtrois branches pour vous protéger des chocs électriques.Cette fiche doit être branchée directement à unconnecteur femelle à trois branches. Ne pas couper ouenlever les branches de la fiche de mise à la terre. Blower/Fan Wiring Diagram Regency I3105...
Page 34
Redéposer les deux dé- le tout en place une fois le nettoyage flecteurs à plat sur les tubes d'air. terminé. Regency I3105...
Page 35
S'assurer que l'isolant repose bien à plat sur le déflecteur et qu'il ne nuit pas à l'évacuation de la fumée. Déposer les poids sur l'isolant, de chaque côté de celui-ci. Regency I3105...
Page 36
être poignée de réglage du tirage, pour utiliser créé par votre poêle Regency, créant un le poêle à son mode le plus efficace. Dans le cas d’une utilisation constante, les tirage descendant dans la cheminée.
Page 37
4) Au moment de vider le tiroir à cendres, assu- d'éviter que des gaz et des flammes rez-vous que les cendres sont complètement 7) Le foyer encastrable Regency peut devenir s'échappent de l'ouverture partielle et refroidies. Les cendres doivent être placées très chaud.
Page 38
Quand le bois brûle lentement, il produit du goudron et d’autres gaz organiques qui se Le fini plaqué or des portes nécessite peu Votre poêle à bois Regency est fourni avec une combinent à l’humidité pour former la créosote. d'entretien. Le nettoyer simplement à l'aide d'un vitre en Neoceram (verre vitrocéramique) de 5 mm...
Page 39
Hex Nut 10-24 Zinc coated 44) * Washer #10 Flat 45) * Bolt, 10-24 x 3/4" Black Carriage 46) 820-484 Stainless smoke deflector 47) 846-103 I3105 Wood Screen 948-216 Regency Logo 918-999 Manual *Not available as a replacement part. Regency I3105...
Page 40
163-572 Black Trim Oversize (Set of 3) 395) * Trim Right Oversize 396) * Trim Top Oversize 397) * Trim Left Oversize 398) * Faceplate Side Oversize 399) * Faceplate Top Oversize *Not available as a replacement part. Regency I3105...
Page 41
PARTS LIST H2105 MAIN ASSEMBLY Part # Description Part # Description 37) 836-212 Baffle Insulation 850-152 Door Assembly - Large Gold 38) * Insulation Weights 850-151 Door Assembly - Large Black 39) 120-950 Steel Baffle 850-153 Door Assembly - Large Nickel Accent...
Page 42
PARTS LIST I3105 & H2105 FIREBRICK Part # Description 120-960 H2105 Brick Set Complete 163-960 I3105 Brick Set Complete 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) * Brick Partial: 1-1/4" x 4" x 9" 72) * Brick Partial: 1-1/4"...
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
Need help?
Do you have a question about the H2105 and is the answer not in the manual?
Questions and answers