Error codes
Display
474
IPM(IGBT Module) or PFCM temperature sensor Error
475
OUTDOOR UNIT fan2 error
484
PFC Overload Error
485
Input current sensor error
500
IPM is overheated
554
Gas leak error
601
Communication error between the CONTROL KIT and wired remote controller
602
Wired remote controller Master/Slave setting error
604
Communication tracking error between the CONTROL KIT and wired remote controller
607
Communication error between the Master and Salve wired remote controllers
901
Water inlet (PHE) temperature sensor error(open/short)
902
Water outlet (PHE) temperature sensor error(open/short)
903
Water outlet (backup heater) temperature sensor error .
904
DHW tank temperature sensor error
906
Outdoor evaporator inlet temperature sensor (open/short)
Flow switch and water pump error (F/S signal is OFF for 10 sec . during the water pump
911
signal is ON)
Flow switch and water pump error (Water pump signal is OFF for 60sec during the F/S
912
signal is ON)
916
Mixing valve temperature sensor (open/short)
38
EHS MONO Kit-EU_IM_05388A-00_EN.indd 38
Explanation
Error Source
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
Wired Remote
Controller
Wired Remote
Controller
CONTROL KIT,
Wired Remote
Controller
Wired Remote
Controller
OUTDOOR UNIT
OUTDOOR UNIT
CONTROL KIT
CONTROL KIT
OUTDOOR UNIT
CONTROL KIT
CONTROL KIT
CONTROL KIT