Samsung MIM-E03*N Installation Manual page 13

Control kit
Hide thumbs Also See for MIM-E03*N:
Table of Contents

Advertisement

Wiring works
Selection for the power and booster heater wire terminal
f Connect the cables to the terminal board using the solderless ring terminal .
f
f Use certified and verified cables .
f
f Connect using a driver which is able to apply the rated torque to the screws .
f
f If the terminal is loose, fire may occur caused by arc .
f
If the terminal is connected too firmly, the terminal may be damaged .
f External force should not be applied to the terminal block and wires .
f
f The cable ties to fasten the wire should be an incombustible material, V0 or above .
f
(The cable ties should be used to fasten the power wire and they are supplied with the unit . )
Tightening Torque (kgf • cm)
M3
M3 . 5
M4
M5
f Main PCB
f
M4 Screw
f ELCB
f
M5 Screw
12
EHS MONO Kit-EU_IM_05388A-00_EN.indd 12
0 . 5 ~ 0 . 7 5
8 ~ 12
12 ~ 18
20 ~ 30
M3 . 5 Screw
M3 . 5 Screw
M3 Screw
2015-03-18 오전 11:53:35