Bc-8060 Star-System™ Network Setup - Datalogic PowerScan PM8300 Product Reference Manual

Hide thumbs Also See for PowerScan PM8300:
Table of Contents

Advertisement

Compatibility with PM8300
BC-8060 STAR-SYSTEM™ NETWORK SETUP
When the BC-8060 cradle model is used in an RS-485 network, it must be
initially configured. To do this using configuration barcodes, follow the pro-
cedure below using any PowerScan™ M8300 reader.
1. Set BC-8060 Address
2. Exit and Save configuration.
3. Read the Bind code to pair the PowerScan™ M8300 to the BC-8060
The green LED on the PowerScan™ M8300 will blink; the reader is ready to
be inserted into the cradle.
4. Firmly insert the reader into the BC-8060 cradle within 10 seconds,
10
four digits for the BC-8060 Address (from 0000 to 1999).
All cradles used in the network must have different addresses.
cradle for configuration.
a beep will be emitted, signaling that the BC-8060 cradle has been
paired to the PowerScan™ M8300, and the green LED on the reader
will go off.
+
Bind
GREEN LED
PowerScan™ PD9330/PBT9300/PM9300