FAULT FINDING AND DIAGNOSIS
Status
Fault
codes
codes
349
EF
CH: Boil Detect, large delta T despite minimum burner load
350
E2
Flow sensor shorted 351 'E2' Flow sensor disconnected
353
--
Burn temporarily blocked due to no 20 minute continuous OFF time in last 24 hours.
354
Overpressure setting erased
357
Primary Heat Exchanger air venting program active - approx. 100 seconds
358
Three way valve kick
359
DHW outlet temperature too hot
364
FA
Gas valve EV2 leak test failed
365
Fb
Gas valve EV1 leak test failed
372
Temporarily ignoring CH requests to limit temperatures of the appliance components
373
8C
SuperLock caused by too frequent thermostat overheat detections during burning
374
8C
SuperLock caused by too frequent ionisation loss during burning
375
E4
Preheat sensor on DHW inlet Short Circuit
376
E4
Preheat sensor on DHW Inlet Open Circuit
380
Inlet temperature greater than DHW Outlet Set point
800
CC
Outdoor sensor defect
808
A7
Domestic hot water sensor defect
810
Domestic hot water remains cold
828
Water pressure sensor defect

7.5.1 SELECTING THE INFORMATION MENU

The Information Menu is a "read only" menu. Information about the boiler
is displayed here, some of the values are updated in real time to give the
current status of the boiler.
All menus time-out after two minutes and the display returns to the
normal operation display, the display backlight turns off after another
30 seconds.
Double up or down arrows indicate that the menu can only be scrolled up
or down, an up and down arrow combination indicates position in the
menu where options can be scrolled either up or down.
To enter Information menu:
1. Press the
button to enter the information menu.
▶ A three figure boiler status code will be displayed along side the
information menu number. Refer to status code table on page 58 for
a description of the boiler status codes.
2. Use the
and
arrow buttons to scroll through the menu items.
▶ Press the
button again to exit the Information menu.
60
eco
°C
reset
ok
°F
e
max
1.
Info
eco
°C
reset
ok
°F
Info
e
max
i 1 203
Fig. 126 Accessing the Information menu
2
1
1
3
0
4
bar
min
max
°C
°F
2
1
1
3
0
4
bar
2.
min
max
°C
°F
6720646608-75.1Wo