4. Lift the heat exchanger until the lower connection clears the hole in
the air box.
5. Pull the heat exchanger towards you to remove.
CAUTION: Component replacement:
▶ After replacement of a gas related component, where
a gasket or seal has been disturbed or replaced, check
for gas tightness using a gas sniffer/analyser.
▶ Also after re-assembly, carry out the following
checks:
Fan pressure in section 6.5,
Flue gas analysis in section 6.6.
▶ Re-assemble in the reverse order.
1.
Fig. 102 Heat exchanger removal

6.8.15 DIVERTER VALVE MOTOR AND DIVERTER VALVE REMOVAL

▶ Disconnect the lead from the diverter valve motor.
1. Pull the diverter valve motor from the housing.
2. Undo and remove the two screws from the diverter valve motor
housing.
3. Pull the diverter valve motor housing from the diverter valve
assembly.
6 720 803 800 (2012/11)
3.
5.
5.
4.
4.
2.
1.
2.
Fig. 103 Diverter valve

6.8.16 DHW TEMPERATURE SENSOR (NTC)

▶ Disconnect the electrical connector from the sensor.
▶ Unclip the sensor from the pipe.
Fig. 104 DHW temperature sensor

6.8.17 PUMP HEAD

Before removal:
▶ Isolate the electrical power to the boiler.
▶ Drain the boiler.
▶ There may be water inside the pump.
Protect any electrical items from water ingress.
1. Disconnect the main electrical connector from the bottom of the
pump.
2. Remove the four screws securing the pump head.
3. Pull the pump free from the housing.
▶ Use a screwdriver to gently disconnect the three wire connector from
the bottom of the pump.