FAULT FINDING AND DIAGNOSIS
7.5

INFORMATION AND SERVICE MENUS

STATUS CODES
During normal boiler operation various Status codes can be displayed by pressing the
The first screen of the Information menu displays the current Status code, this will change as the boiler runs through the various modes and sequences.
These are not always faults, but just provide information concerning the current status of the boiler.
Status
Fault
codes
codes
200
CH System is being heated
201
DHW system is being heated
202
Anti rapid cycle mode
203
System stand by
204
System waiting, primary flow temperature above setpoint
205
Waiting for airflow
207
CE
System pressure too low
208
Test mode active due chimney switch
210
E9
Flue-gas thermostat activated
211
TTB opened (thermal kickback device)
212
Safety or flow temperature rises too fast
213
D4
Temperature difference between supply and return exceeding limit
214
C7
Fan not running
215
C6
Fan running too fast
216
C6
Fan running too slow
217
C7
No airflow after defined period of time
218
E5
Flow temperature too high
219
E9
Safety sensor temperature too high
220
E9
Safety sensor shorted
221
E9
Safety sensor disconnected
222
E2
Flow sensor shorted
223
E2
Flow sensor disconnected
224
E9
MAX thermostat activated
225
Difference between flow and safety exceeding limit (bi-sensor only)
227
EA
No ionisation detected after ignition
228
F7
Ionisation current detected before burner-start
229
EA
Loss of ionisation signal during operation
230
EA
Ionisation signal out of bounds
231
FD
Mains power error - electrical power interruption
232
D3
external cut-off switch activated
233
9U
HCM problem
234
EA
Gas valve coil disconnected
237
C4
Airflow present during last 24 hours - fan running continuously
238
F0
Gas valve error
239
F0
Watchdog relay error
240
D1
Return sensor shorted
241
D1
Return sensor disconnected
242 to 256 F0
Internal error call Bosch helpline 0844 892 3366
257
b7
Internal error - replace control board
258 & 259 F0
Internal error call Bosch helpline 0844 892 3366
260
No temperature rise after burner start
261
EA
First Safety timing error
262 & 263 F0
Internal error call Bosch helpline 0844 892 3366
264
C1
Airflow stopped during operation
265
Stand-by mode forced due to energy transfer limit
266
CE
No pressure variation detected after switching pump
267
F0
Watchdog timeout error
268
Component test mode
269
EA
Ignition device activated too long
58