1
Wall mounting frame
2
Expansion vessel
3
CH return isolating valve
4
DCW mains isolating valve
5
Gas isolating valve
6
DHW outlet connection
7
CH flow isolating valve
8
Condensate drain connection
9
Flue connector
10
Flue overheat thermostat
11
Main superstructure
12
Case
13
Case retaining screws
14
Bottom panel
15
Case retaining clips
16
Control panel
17
Control panel menu buttons
18
Blank for optional programmer
19
Diagnostic port - Worcester service engineer
20
Pressure gauge
21
DHW temperature control
22
Boiler identification label
23
Operation/fault indicator (blue)
24
Control panel flap
25
Boiler fascia guide location
26
CH temperature control
27
Boiler display
28
Fan
Table 4 Boiler components
BOILER FEATURES
• High pressure die-cast aluminium heat exchanger
• Low NOx emissions
• Fixed gas valve settings
• Direct burner ignition
• Zero pressure governor gas valve with fully modulating fan
• Display for boiler status and access to diagnostics, system and
commissioning parameters
• Digital control system
• Memory retention after power interruption
• Low electrical power consumption during operation and stand-by
modes
• Modulating pump
• Condensing in CH and DHW modes
• Three star Hot Water Comfort measured to EN13203 Part 1 in
comfort mode with DHW pre-heat ON
• Eco mode, to use gas on demand
• Plate type DHW heat exchanger
• Ability to pre-plumb condensate drain, CH flow, DHW Outlet, Gas,
DCW In, PRV and CH Return connections
• Syphonic condensate trap
• Galvanised steel wall mounting frame
• Standard wall frame provides vertical pipe route behind the boiler
• Compatible with all Worcester standard and intelligent controls
• Condensfit II flue systems 60/100 and 80/125 mm allows plume
re-direction as standard and ability to attach plume management kits
6 720 803 800 (2012/11)
29
Flow temperature sensor (NTC)
30
Electrode assembly
31
Maximum safety sensor (NTC)
32
Auto air vent
33
Aluminium Silicon Heat exchanger
34
Flueway
35
Sump assembly
36
Pressure gauge connection point
37
Diverter valve actuator (stepper motor)
38
Diverter valve body
39
Modulating pump
40
Drain point
41
CH return connection to isolating valve
42
PRV
43
DCW in connection to isolating valve
44
PRV Connection pipe
45
Gas pipe from isolating valve
46
DHW outlet pipe
47
DHW temperature sensor (NTC)
48
CH flow pipe to isolating valve
49
Condensate siphon drain pipe
50
Condensate siphon
51
DHW Plate heat exchanger
52
Expansion vessel connection
53
Return temperature (NTC)
54
Gas valve
55
Combustion air inlet
56
Ignition transformer
APPLIANCE INFORMATION
7