FAULT FINDING AND DIAGNOSIS
Cause
Fault codes
codes
Description
F0
237
Internal error
238
Gas valve error
239
242 - 256
258
259
Internal error
262
263
267
272
279
290
278
Sensor test failed
280
Recycle time error
338
Too many short burner starts
without confirmation
F7
228
Flame error
328
Internal error
FA
306
False flame error
FD
231
Mains power error
FA
364
Gas valve EV2 leak test failed
Fb
365
Gas valve EV1 leak test failed
Table 21 Locking fault and cause code listing
BLOCKING ERRORS
Fault
Cause
code
code
Description
A1
281
Pump stuck or running in air
C1
264
Airflow stopped during operation
C4
273
Airflow present during last 24 hours
D1
240
Return sensor short circuit
241
Return sensor disconnected
D4
271
Temperature difference between flow and
safety sensors exceeds limit
Table 22 Blocking codes
68
Reset type
Possible cause
Call Worcester, Bosch Group
Technical helpline 0844 892 3366
Reset button
Leaking gas valve
Call Worcester, Bosch Group
Technical helpline 0844 892 3366
Reset button
On power up all safety sensors are checked.
Check has failed.
Reset button
After the burner has stopped, the recycle mode purges gas from the
heat exchanger before attempting to burn again. The software has 3.1
seconds to intervene before the boiler goes into this fault condition.
Reset button
There is an error where the pump is not detecting water.
Reset button
False flame. Flame detected before burner start.
Replace control board
Reset button
Flame detected after burner stop
Reset button
Electrical power interruption.
Reset button
Gas valve leak.
Reset button
Gas valve leak.
Possible cause
Little or no water in the system.
Fan has stopped.
Fan has been running continuously during the past 24 hours.
Wet sensor.
Blocking for 300 secs before going to Locking error ( table 21).
Blocking for 300 secs before going to Locking error ( table 21).
The temperature of the primary flow and the safety sensor on the WB7 should
be within 15°C of each other.