i1
Current status
Every operation and mode of the
boiler has a related boiler status code.
The boiler status code is displayed on
the screen as a three figure number.
Refer to table on page 58 or error
table for information on the boiler
status codes.
i2
Last error
This can be viewed during normal
operation. Displays the last diagnostic
code with boiler status code.
i3
Maximum heating
The maximum possible heat output is
output
displayed in kW. The boiler may have
the maximum output reduced via
Menu 3.1A
i6
DHW flow rate at 40 °C
The screen displays the current DHW
temp. rise ± 15%.
flow rate in litres per minute to one
decimal place.
i7
Supply temperature
This is the temperature set point for
setpoint
the primary flow from the main heat
exchanger. (This will be zero during
HW demand.)
i8
Ionization current
The ionization current should be equal
to or greater than
35 μA (micro Amps).
i9
Flow temperature
This is the actual temperature from
the main heat exchanger displayed in
real time.
i10
Maximum temperature This is the current temperature from
the "Maximum safety sensor". This
sensor is mounted on the front of the
heat exchanger.
i11
DHW flow temperature The current DHW flow temperature.
i12
DHW temperature
This is the temperature selected via
setpoint
the Hot Water control knob on the
fascia.
i14
Return temperature
The current temperature returned to
the main heat exchanger.
i15
Outdoor temperature
i16
Pump modulation
The current pump modulation is
displayed as a percentage.
i17
Burner modulation
The current burner modulation is
displayed as a percentage.
i18
Fan speed
The current fan speed is displayed in
Hertz. The value is up-dated in real
time.
i19
Time inputs
This indicates the status of the
optional fascia mounted controls:
0 = CH off, DHW off
1 = CH off, DHW on
2 = CH on, DHW off
3 = CH on, DHW on
i20
Software version
Firmware version of the main control
board.
i21
Software version
Firmware version of the fascia control
display board
Table 17 Information menu listing
6 720 803 800 (2012/11)
i22
Heat Control Module
The last three digits of the HCM are
(HCM) number.
displayed:
332 = 28kW Combi N.G.
333 = 28kW Combi L.P.G.
334 = 32kW Combi N.G.
335 = 32kW Combi L.P.G.
372 = 36kW Combi N.G.
373 = 36kW Combi L.P.G.
i23
Heat Control Module
For example "4"
(HCM) version number.
Table 17 Information menu listing