6.8.16 SYPHON REMOVAL

Removal of the syphon assembly will give access to the

Auto Air Vent.

To release the syphon from the sump:
1. Disconnect the discharge hose from the condensate outlet pipe.
2. Using a screwdriver, disengage the retaining clip on top of the syphon.
3. Pull the syphon towards you and remove the complete assembly.
3.
1.
Fig. 119 Syphon removal

6.8.17 DIVERTER VALVE MOTOR

▶ Connect electrical power to the appliance.
▶ Enter the service mode to ensure that the diverter valve is in the mid
position (there is no need to drain the appliance).
▶ Electrically isolate the appliance.
▶ Remove diverter valve cover, if fitted.
▶ Disconnect the electrical connector from the diverter valve motor.
1. Pull the motor assembly towards you.
The assembly will slide free from the valve.
▶ To fit the new diverter valve motor, slide the body into the housing.
▶ Ensure that "H" section of the motor actuator is fitted correctly into
valve body.
▶ Re-connect the electrical connection.
▶ Re-fit the protective cover (if available).
2.
1.
Fig. 120 Diverter valve and motor
6 720 802 047 (2013/05)
2.
6720643895-56.2Wo
3.
6720643895-84.1Wo

6.8.18 DIVERTER VALVE

To ease assembly of components, apply silicone
lubricant to sealing surfaces.
▶ Ensure the appliance has been fully drained.
▶ Disconnect the electrical connector from the diverter valve motor.
▶ Remove the diverter valve cover, if fitted.
2. Undo the two screws holding the valve to the plastic housing.
3. Withdraw the valve and clean the valve chamber if necessary.
▶ To refit, follow the above in reverse.
▶ Ensure any seals that have been disturbed are renewed.
6.8.19 AUTO AIR VENT
Removal of the syphon assembly will give access to Auto
air vent. Refer to page 47.
▶ Ensure the appliance has been fully drained.
▶ Use a screwdriver or similar to rotate the air vent anti-clockwise, as
shown below.
Fig. 121 Auto air vent
1. Lift the air vent (1) out of the housing and remove.
Fig. 122 Auto air vent removal
NOTICE:
▶ The "O" ring must be fitted to the Auto air vent and
NOT the hydraulic block otherwise the Auto air vent
will be difficult to fit.
▶ Apply silicone lubricant to the "O" ring to ease
assembly.
▶ To refit, follow the above in reverse.