Mitsubishi QJ71NT11B User Manual page 14

Melsecnet/h network module
Table of Contents

Advertisement

(2) Station number/Mode setting switches
Used to set the station number and mode of the network module. (Factory
default setting: 1)
Set the same operation mode to all network modules.
10 10s unit
1 1s unit
(3) Spring clamp terminal block
Used to connect a twisted pair cable or CC-Link Ver. 1.10-compatible cable
(Refer to Section 5.1.2 (2)(b)).
(4) Serial number plate
Indicates the serial number of the network module.
Setting
10
0
0
3
3
TEST
TEST
TEST
TEST
*1: The ERR. LED does not turn on in red if the station
number is set equivalent to 33 to 64.
1
0
(The ERR. LED turns on.)
1
Station number 1 to 32 (online.)
to
2
3 to 9
0 to 9
(The ERR. LED turns on.) *1
0 to 6
7
8
Internal self-loopback test
9
7
Indication
Setting error
Setting error
Self-loopback test
Hardware test