SERVICING, MAINTENANCE AND
COMPONENT REPLACEMENT
Replacement of air filter
Cool the appliance and disconnect from supply. Turn the hob on its back or side
without scratching the cooking surface.
Push the slide latch (Fig 4) and lift the filter cover away from the base. Replace the
used filter with a new one. Reverse the procedure to re-fit the cover. Do not
operate the appliance without a filter, as dirt and grease could be drawn into the
electronics, impairing safe operation.
A Latch
B Cover
C Filter
D On/Off switch
All other servicing, maintenance and component replacement on this appliance
should be carried out by one of our recommended service engineers.